AKD PDMM User Guide | 30.1 FAULTx.ACTION
30.1 FAULTx.ACTION
General Information
Type
R/W
Description
Gets/Sets the Fault Action for Fault 130, 131, 132,
134, 139, 451, and 702.
Units
N/A
Range
0 to 1
Default
Value
0
Data Type
Integer
Start Ver-
sion
M_01-04-16-000
Description
This Parameter determines the action the drive should take when Fault 130, 131, 132, 134, 139,
451, or 702 occurs.
Parameter Value
Drive Action
0
Disable Ampllifier
1
Ignore (fault will not be reported)