TP-6461 1/08
95
Section 6, Component Replacement, Model KSS Switches
Figure 6-16
Checking Diode Operation of Rectifier
Solenoid Replacement
Spring-loaded parts.
Can cause severe personal injury
or property damage.
Wear
protective
goggles
when
servicing spring-loaded parts. Hold
parts securely during disassembly.
WARNING
Disassembling the solenoid. Spring-loaded parts can
cause severe personal injury or property damage.
The
spring in the solenoid assembly exerts substantial force on the
coil. Hold the coil assembly securely when removing the
screws.
12. Remove tie wraps, as necessary.
Note:
Do not cut the insulation on the wiring.
13. Remove the front bolt of the coil securing the strap.
See Figure 6-17.
14. Loosen the rear bolt of the coil securing the strap.
15. Remove the coil.
Note:
The plunger assembly is spring-loaded.
See Figure 6-18.
Figure 6-17
Coil Securing Strap
Figure 6-18
Spring and Plunger Assembly