Appendix
Error code
SPN
FMI
Designation
516512
31
Starters - Not connected in the output 2 to engine control unit
1076
6
Volume control valve - Critical high output current
1076
0
Volume control valve - Critical overcurrent
1076
1
Volume control valve - Critical undercurrent
516251
11
Volume control valve - Current remains above the set point
516252
11
Volume control valve - Current remains below the set point
516330
11
Volume control valve - Electrical error
1076
5
Volume control valve - Open circuit
516253
11
Volume control valve - PWM signal - High limit reached
516254
11
Volume control valve - PWM signal - Plausibility error
1076
11
Volume control valve - Short circuit load
1076
3
Volume control valve - Short circuit to battery high side
516328
3
Volume control valve - Short circuit to battery low side
1076
4
Volume control valve - Short circuit to ground high side
516329
4
Volume control valve - Short circuit to ground low side
516255
6
Volume control valve 2 - Critical high output current
516255
0
Volume control valve 2 - Critical overcurrent
516255
11
Volume control valve 2 - Critical undercurrent
516256
11
Volume control valve 2 - Current remains above the set point
516257
11
Volume control valve 2 - Current remains below the set point
516336
11
Volume control valve 2 - Electrical error
516255
5
Volume control valve 2 - Open circuit
516258
11
Volume control valve 2 - PWM signal - High limit reached
516259
11
Volume control valve 2 - PWM signal - Plausibility error
516255
11
Volume control valve 2 - Short circuit load
516255
3
Volume control valve 2 - Short circuit to battery high side
516336
3
Volume control valve 2 - Short circuit to battery low side
516255
4
Volume control valve 2 - Short circuit to ground high side
516336
4
Volume control valve 2 - Short circuit to ground low side
5386
6
Wastegate valve - Critical high output current
5386
11
Wastegate valve - Electrical error
5386
5
Wastegate valve - Open circuit
516318
31
Wastegate valve - Short circuit load
5386
3
Wastegate valve - Short circuit to battery high side
516266
3
Wastegate valve - Short circuit to battery low side
5386
4
Wastegate valve - Short circuit to ground high side
516266
4
Wastegate valve - Short circuit to ground low side
97
5
Water in fuel sensor - Open circuit
KD62V12 33521030301_8_1 EN_US 2022-09
© 2022 by Kohler Co. All rights reserved.
181
Содержание KD62V12
Страница 6: ...6 2022 by Kohler Co All rights reserved KD62V12 33521030301_8_1 EN_US 2022 09...
Страница 8: ...8 2022 by Kohler Co All rights reserved KD62V12 33521030301_8_1 EN_US 2022 09...
Страница 163: ...Operating faults Faults Cause Remedy KD62V12 33521030301_8_1 EN_US 2022 09 2022 by Kohler Co All rights reserved 163...
Страница 210: ...33521030301_8_1 EN_US 2022 09 LHID12566146 2022 by Kohler Co All rights reserved...