Maintenance
Generic maintenance activities
u
Release and remove ratchet wrench.
w
The tensioning device is released.
Fig. 52: Checking drive belt tension — Measurement area
1
Sensor
2
Belt section
u
Check tension with frequency meter. The measured frequency value must be 165 Hz (Min 149
Hz - Max 182 Hz).
In case of air conditioning compressor installed, proceed in the same way.
Information
Install battery charging alternator cover in reverse sequence.
5.8.1 Removing the battery charging alternator cover, page 106.)
5.8.4 Replacing tensioning device — SL110
q
Battery charging alternator cover is removed.
(For more information see: 5.8.1 Removing the
battery charging alternator cover, page 106.)
q
Drive belt is removed.
(For more information see: 5.8.3 Replacing drive belt — SL 109,
q
New tensioning device is available.
KD62V12 33521030301_8_1 EN_US 2022-09