Maintenance
Cooling system
At drain holes 1:
u
Check for leaks.
In case of water leaks:
u
Leaking of condensation water is not an issue. Let the condensation water flow out.
In case of air leaks:
u
Air leaks are normal.
In case of leaks of water mixed with antifreeze:
u
Inspect charge air cooler for leaks. If necessary, make sure that the leaks are repaired by the
authorized service personnel.
5.10.4 Checking relief bores — coolant pump — SL003
q
Preparatory maintenance activities are fulfilled.
(For more information see: 5.5 Preparatory
maintenance activities, page 98.)
DANGER
Hazards by ejection of hot operating fluids or filler cap.
Hot fluid spray from a pressurized cooling system will result in death or serious injury by burns.
Filler cap ejected by operating fluid under pressure will result in death or serious injury by
impact.
u
Only perform maintenance and inspection work on the cooling system when the engine has
cooled down to ambient temperature.
u
Wear proper personal protective equipment.
Fig. 74: Relief bores on coolant pumps
1
Coolant pump high temperature
2
Coolant pump low temperature
KD62V12 33521030301_8_1 EN_US 2022-09
© 2022 by Kohler Co. All rights reserved.
127
Содержание KD62V12
Страница 6: ...6 2022 by Kohler Co All rights reserved KD62V12 33521030301_8_1 EN_US 2022 09...
Страница 8: ...8 2022 by Kohler Co All rights reserved KD62V12 33521030301_8_1 EN_US 2022 09...
Страница 163: ...Operating faults Faults Cause Remedy KD62V12 33521030301_8_1 EN_US 2022 09 2022 by Kohler Co All rights reserved 163...
Страница 210: ...33521030301_8_1 EN_US 2022 09 LHID12566146 2022 by Kohler Co All rights reserved...