TROUBLE SHOOTING
Symptoms
Probable Causes
Corrective Action
No soap dispensed
(Display on panel)
Replenish soap solution
Clean soap dispenser pipeline
Activate auto clean soap solution function
Inspect soap dispenser wiring and hose
Press button on control box and manually extract
soap solution according to installation steps
Deactivated
(No display on panel, no
water and soap flows)
No power supply or incorrect wire
connection (AC)
Inspect general power and wiring condition
Other objects within sensing range
Dirty sensing window
Improper or wrong terminal connection engagement
Angle valve is closed
Filter device is blocked
Clogged foam soap cartridge
Remove objects
Clean window
Inspect terminal
Open valve
Clean filter
Clean foam cartridge
The stop valve is not open completely
The Aerator
is blocked
The filter is blocked
The supply water pressure is low
Open the angle valve
Clean
aerator
Clean filter
Check the water supply system
Low flow
Water runs for longer than
1 minute without switching off.
Object in sensing range
Remove object
Clean residual water on the induction window
Soap used up
Clogged soap dispenser pipeline
Improper soap dispenser connection
No manual soap solution extraction
performed after initial installation
No water flows
(Panel display)
Please contact with distributor or Kohler China Investment Co., Ltd., if the trouble remains after above-mentioned actions are taken.