background image

1380339-T01-A

6

五 连接电源和控制线

1.

将龙头电源线与控制盒对应接头

连接并插紧

(见图

4

2.

将皂液器电源线与控制盒对应接

头连接并插紧

(见图

5

3.

客户根据需要自备穿线管及连接

线,建议交流电源线采用带绝缘护
套 层 的 电 线 , 导 体 标 称 截 面 积

 

≥0.5mm

2

将图示从接线柱引出的

线与交流电源线相连接(

见图

6

)

4.

接线完毕后,应检查并确保所有

排、接线无误。盖上控制器盒盖,
打开交流电源,使龙头进入工作状
态。

六 添加皂液

1.

按下皂液瓶拆卸按钮,将皂液瓶

向下拉,从皂液泵上拆下

(见图

7

2.

向皂液瓶内添加适用的

粘度

1

4000MPa·s

液体皂液。

3.

把皂液吸管插入皂液瓶内,将皂

液瓶装

复位

并向上推,直到听

到“咔嗒”声

(见图

8

4.

初次添加皂液后,按住控制盒盖

上的按钮约

2~3

秒,直到皂液泵启

动;皂液泵将工作一段时间后自动
停止,将皂液瓶内的皂液抽取到龙
头内。如果皂液没有从龙头流出,
重复该步骤,直到皂液从龙头流出

(见图9)

5.

Connect power supply and control

 wire

1. Connect and tighten faucet wire to

corresponding connector on control box
 (Fig.4) . 

2. Align soap dispenser wire to
corresponding connector on control box 
and tighten properly (Fig.5). 

3. Customer shall prepare proper wire hose
and connecting wire. It is suggested that AC 
wire shall adopt insulated harness. The 
nominal cross-sectional area of conductor is 
≥0.5mm

2

Connect wire from terminal to 

AC power cord as shown. 

(Fig.6). 

4. After wiring work is completed, check ad
ensure proper wiring and connection. Close 
control box cover and turn on AC power 
supply to activate faucet working status. 

6.

Replenish soap solution

1. Press soap dispenser dismantle button
and pull soap container down, and remove 
from soap pump (Fig.7). 

2. Fill soap solution into soap container.

3. Insert soap suction tube into soap
container, reinstall soap container to 
original place and push up until the “click” 
sound is heard (Fig.8). 

4. Press button on control box cover for
2~3s after initial soap replenishment until 
soap pump activated; soap pump will auto 
stop after a period of time and the soap will 
be extracted to the faucet. If there’s no 
soap flow out from the faucet, repeat this 
step until soap flows out (Fig.9). 

Fig.8

8

Fig.9

9

Fig.6

6

Fig.4

4

Fig.5

5

Fig.7

7

Содержание AVID DUO 29936T-CP

Страница 1: ...ing window when installing or cleaning the faucet 4 For new installations install the faucet and drain to the lavatory before installing the lavatory BEFORE YOU BEGIN 158 200436 1955 200444 AVID AVID...

Страница 2: ...l light up indicating waving hand for soap solution After clean both hands extending hands under the faucet sensing range again The faucet begins to flow The faucet will auto stop water flow within 0...

Страница 3: ...in AVID DUO SENSOR FAUCET AC MIXOR AVID DUO SENSOR FAUCET AC COLD Drain 54 41 2 66 5 31 75 226 191 123 151 135 50 5 Finish the wall Switch 100 Recommended Size 200 Recommended Size 500 Recommended Siz...

Страница 4: ...17 15 8 18 1 2 Install Control Assy TECHNICAL SPECIFICATION 48 2 2 4 3 37 5 61 16 15 17 18 Mixer 19 Cold 10 11 12 14 13 Insert faucet soap hose 9 wire 8 and inlet hose 7 through gasket 2 then seat ga...

Страница 5: ...oap dispenser pump Fig 3 4 How to Install the Drain Unscrew the drain flange 22 from drain assembly Apply plumbers putty around the bottom circle Insert drain body 23 into lavatory from the underside...

Страница 6: ...d ensure proper wiring and connection Close control box cover and turn on AC power supply to activate faucet working status 6 Replenish soap solution 1 Press soap dispenser dismantle button and pull s...

Страница 7: ...ith temperature mixture turn off hot water valve first and then turn on the water and adjust to full cold slowly turn on hot water valve to avoid scalding If cold water pressure is high and unable to...

Страница 8: ...ersely affect the surface and it is not recommended for cleaning Do not use abrasive cleaners or solvents on Kohler faucets and fittings HOW TO CHANGE TO A THERMOSTATIC SENSOR FAUCET If users purchase...

Страница 9: ...ntrol assembly water inlet 3 24 JMP1 1 2 24 JMP2 1 2 3 Self Cleaning the stagnant water When the faucet is no used for a long period of time it will automatically flush to discharge the stagnant water...

Страница 10: ...is closed Filter device is blocked Clogged foam soap cartridge Remove objects Clean window Inspect terminal Open valve Clean filter Clean foam cartridge The stop valve is not open completely The Aera...

Страница 11: ...10 Pb Hg PBB PBDE Cd Cr VI GB T 26572 GB T 26572 10 1380339 T01 A 11...

Страница 12: ...f these hazardous materials used in this product The product service life for environment protection is 10 years Kohler Company will specify product service life based on product characteristics The p...