Chapter 4
MDP-621/641/640
Installation Operation
manual
4.5.1.3
Interconnecting cable (RB716A)
(1) Be sure that the power is off.
(2) Use a socket wrench to remove the back cover of scanner unit.
(3) Remove the two bolts securing the transceiver.
(4) Remove the connectors to the motor X1 and to the heading switch X2. Pull out the transceiver,
and put it separates over 5cm from iron.
(5) Remove the two bolts securing the fixing plate at the cable entrance.
(6) Remove the metal fixing plate, rubber seal and washer that secure the cable. Pass the cable
through as shown in the diagram below; replace the above items and tighten the bolts.
(7) Return the transceiver to its original position and secure it with the bolts you removed.
(8) Connect the 7-pin connector to X11 and the 9-pin connector to X12 of the printed circuit board and
connect the two connectors that you removed in Step 3).
(9) Reattach the scanner cover. Take care not to pinch the cable when reattaching the cover.
(10) Connect the cable to the plug labeled "SCANNER" on the rear panel of the display unit. Be sure
to secure the rubber boot around the cable connector rim.
4-12
0093161022-06