Chapter 9
MDP-1241/1240/1260/1210
Navigation Data operation
Operation manual
(2) Anchor watch
The anchor slip alarm sounds (Beep!, Beep!, Beep!) if own ship drifts outside a preset alarm area
while at anchor.
To activate the anchor watch alarm, set up the alarm area and then set ALARM to ON.
NAV/PAGE1/ALARM
ARR AL
XTE
TEMP
SPEED
ANCHOR
RETURN
NAV
PAGE1
NAV/PAGE1/ALARM/ANCHOR
NAV
PAGE1
RETURN
ALARM
ON
AREA
XXX
ALARM
OFF
Turns the
anchor alarm
ON/OFF.
AREA 0.05
If the AREA key is pressed, the adjustment box is
displayed and the alarm area is set with the rotary
control.
Designated area: 0
〜
9.99nm
Initial setting: 0.05nm
(3) Course deviation alarm
The course deviation alarm sounds (Beep!, Beep!, Beep!) if own ship deviates outside a preset
alarm area (range).
Activate the alarm by setting up the destination/route navigation and then set the ALARM to ON.
NAV/PAGE1/ALARM
ARR AL
RETURN
XTE
TEMP
SPEED
ANCHOR
NAV
PAGE1
NAV/PAGE1/ALARM/XTE
RETURN
AREA
XXX
ALARM
ON
NAV
PAGE1
ALARM
OFF
Turns the course
deviation alarm
ON/OFF.
0.05
AREA
If the AREA key is pressed, the adjustment box is
displayed and the alarm range is set with the
rotary control.
Designated area: 0
〜
9.99nm
Initial setting: 0.05nm
9-6
0093161202-06