Chapter 5 Troubleshooting and on board repair
MDC-7000/7900 Series
5-20
0092669002-07
2
Change motor brushes with new set.
Is motor brush length within
nominal value (at least 6 mm) ?
No
Yes
Motor failure
Failure of motor power or wiring in
antenna unit, or failure of Display
unit power
Yes
Is motor drive power (24V for J2-5
to J1-5) normal?
No
1
Yes
Motor driver PCB failure.
Is motor drive power (24V for TB1,
2 and 3) normal?
Motor failure
No
Is used brushless motor?
Yes
2
No
Failure of motor power or wiring in
antenna unit, or failure of Display
unit power
Yes
Is motor drive power (24V for J2-8
and J1-8) normal?
No