Caution Item on Handling
Caution on the rotating aerial
The radar antenna may start to rotate without notice. Please
stand clear from the antenna for your safety.
Caution
Caution on electromagnetic disturbance
The operating Antenna & Scanner unit radiates high-energy electromagnetic
wave. It may cause harmful effect for human body due to its continuous
irradiation. As International regulation says, electromagnetic waves less than
100 watt/m
2
does not have a harmful effect on human bodies, but some kind of
medical devices such as heart pacemakers are sensitive even under the low
energy electromagnetic wave. Any personnel with such a device should keep
away from the electromagnetic wave generating position at all times.
Specified power density and distance from the radar (in accordance with the
provision as specified in IEC 60945)
Model
Xmit power/Antenna length
100W/m
2
10W/m
2
MDC-2041
4kW/ 2 feet (Radome antenna)
0.8m
2.54m
MDC-2040
4kW/ 3 feet (Open antenna)
0.9m
2.85m
4kW/ 4 feet (Open antenna)
1.01m
3.2m
MDC-2060
6kW/ 4 feet (Open antenna)
1.09m 3.46m
6kW/ 6feet (Open antenna)
1.3m 4.10m
MDC-2010
12kW/ 4 feet (Open antenna)
1.55m 4.89m
12kW/ 6feet (Open antenna)
1.84m 5.81m
Содержание MDC-2000 series
Страница 1: ......
Страница 2: ......
Страница 72: ...MDC 2000 Series Chapter 6 Attached Table 0093120005 02 6 1 Chapter 6 Attached Table 6 1 Menu Configuration ...
Страница 73: ...Chapter 6 Attached Table MDC 2000 Series 6 2 0093120005 02 ...
Страница 74: ...MDC 2000 Series Chapter 6 Attached Table 0093120005 02 6 3 6 2 Specifications ...
Страница 75: ...Chapter 6 Attached Table MDC 2000 Series 6 4 0093120005 02 6 3 External View Unit mm inch ...
Страница 82: ......