System Operating Procedures
October 2002
3-41
Setting the Development Time Tolerance
A “DRIVE ERROR” message appears on the OCP when the development time is
slower or faster than the set speed by more than its set tolerance. The information
in this procedure enables you to change the tolerance.
1.
Use the
Up
or
Down Arrow
to select the desired setup (A or B) and the
tolerance screen.
2. Press
Set
to access the screen in Set mode.
3. Use
the
Up
or
Down Arrow
to adjust the acceptable tolerance range. The
adjustments are in one second increments.
4. Press
Set
to cancel the Set mode.
5. To save any changes and return to normal operation, press both
Reset
keys
simultaneously.
NOTE: To make other changes, select the desired screen and enter new
values.
Setting the Chemical Temperature Tolerance
This must be done by a qualified Kodak service person.
Clearing Error Conditions
Refer to the following procedures to clear error conditions:
•
“Clearing Drive Errors” on page 5-18
•
“Clearing Processor Paper Jams” on page 5-18
•
“Clearing a Reset Message” on page 5-17