Specifications
B-10
October 2002
Operating Environment
If the environmental temperature changes more than 3
o
Celsius (5
o
Fahrenheit)
since the printer was last calibrated, calibration is necessary to maintain the
image quality of the prints.
The printer operates in typical office under the following conditions:
*
Stabilizer wash: 27
o
C (80
o
F) maximum
Water wash: 30
o
C (86
o
F) maximum
A plumbed processor with a water wash system is required for environments
with temperatures above 27
o
C (80
o
F). For more information, see “Plumbing”
on page B-3.
**
Although the printer and processor operate in normal room lighting, access to
a darkroom is required to load the paper into the paper cassettes. Do not
operate the printer in areas with intense lighting.
NOTE: The operating environment should be free of smoke and excessive dust.
Venting the Processor
At least 10 complete air changes per hour are required for the room that the
processor is in. Whenever possible, vent the processor directly to the outside in
accordance with local, state and federal regulations.
NOTE: A 7.6 cm (3 in.) processor vent kit is available from Kreonite Inc. for rooms
that have less than 10 air changes per hour.
Air conditioning requirements:
The Printer generates 7,509 BTU/hr.
The Processor generates 18,020 BTU/hr.
Temperature
Relative Humidity
Altitude
Lighting
(Maximum)
15
o
to 30
o
C
(59
o
to 86
o
F)*
15% to 76%
(40% to 55%
recommended)
0–2000 m
(0–6562 ft.)
325 lux* *
(30.2 ft.
candles)
Содержание Professional RP 50
Страница 1: ...KODAK PROFESSIONAL RP 50 LED Printer Operator s Guide Part No 2J0686 ...
Страница 16: ......
Страница 74: ......
Страница 90: ......
Страница 118: ......
Страница 122: ......
Страница 146: ...Additional Calibration Information C 12 October 2002 Value Graph ...
Страница 147: ...Additional Calibration Information October 2002 C 13 Difference Graph ...
Страница 168: ......
Страница 190: ......
Страница 197: ......