37
E
nglish
OPERATION
cont.
→ Drain Valve:
The drain valve is located at the base of
the air tank and is used to drain condensation at the end
of each use. Turn counterclockwise to OPEN and clock-
wise to close. The air bubble should be always in
the Red circle.
Drain Valve
→ Check Valve:
When the air compressor is operating, the
check valve is „open,“ allowing compressed air to enter
the air tank. When the air compressor reaches “cut-out“
pressure, the check valve „closes,“ allowing air pressure
to remain inside the air tank.
Check Valve
BEFORE FIRST USE
BREAKING IN THE COMPRESSOR
WARNING
Serious damage may result if the following break-in instructions are not
closely followed.
Always follow this procedure before you use the air compressor and when the check valve or a
complete compressor pump has been replaced.
→
Make sure the Auto / Off switch is in the OFF position.
NOTE:
Pull the coupler back until it clicks to prevent air from escaping
through the quick connect.