Q-0600 Compressor Replacement
Installation Instructions
NOTE: THIS REPLACEMENT IS ONLY FOR THE Q-SERIES MACHINES. NO CHANGES WITH
START/RUN COMPONENTS ARE NEEDED.
1.
Disconnect power to the ice machine at the electrical
disconnect (moving the toggle switch to the off
position will not disconnect line voltage).
2.
Remove panels (top, front, left and right sides).
3.
Recover refrigerant from ice machine.
4.
Remove right side corner post (when facing the front
of the machine) and back panel.
5.
Remove wiring from compressor terminals.
6.
Cut tubing (suction, discharge, and process lines) at
the compressor ports.
7.
Remove compressor from machine. Make sure to
crimp and braze shut ports to compressor.
8.
Remove extra section of suction service valve
process tube from the ice machine at swedge joint.
Repeat this procedure with discharge line. Remove
up to T section.
9.
Insert new compressor into the machine as shown.