CONDENSATE ESCAPING THROUGH THE MASONRY.
ELEMENTS TO CHECK
ORIGIN
Flue gas channel
Flue
Condensate tray
Use of inadequate material;
Absence of or incorrect installation of the
dedicated condensate collector with drain
connected to the disposal system.
SELF-COMBUSTION INSIDE THE FLUE.
ELEMENTS TO CHECK
ORIGIN
Hood fitting/flue gas
channel
Flue gas channel
Flue
Periodical cleaning not performed.
WATER INSIDE THE HEATING COOKER/HEATING STOVE.
ELEMENTS TO CHECK
ORIGIN
Flue
Chimney
In the event of the total or partial absence of a
chimney, the flue has not been installed
parallel to the appliance;
Inadequate chimney.
Pump thermostat
Pump start-up at temperatures that are too
low (condensate is created).
THE OVEN AND HOB DO NOT HEAT UP.
ELEMENTS TO CHECK
ORIGIN
Smoke damper
Closed or badly adjusted.
Oven regulator
Closed or badly adjusted.
Combustion air damper
Closed or badly adjusted.
See “INSUFFICIENT DRAUGHT” page 58
See “The oven and hob" page 43
To prevent flue gas from escaping when loading wood, close the
ash drawer and its air inlets completely and fully open the smoke
damper.
Содержание K top
Страница 1: ...INSTALLATION USE AND MAINTENANCE USEFUL ADVICE Heating cooker Heating stove User guide EN...
Страница 2: ...2...
Страница 5: ...5 HEATING COOKERS and HEATING STOVES models K top KP top and models TS top TSP top S R L...
Страница 15: ...15 Top view of heating stove 600 665 622 275 515 170 150...
Страница 49: ...49 Loosen the two hex screws on the inspection vent 1 2...
Страница 50: ...50 Remove the vent as shown in the diagram and remove any deposits under the oven...
Страница 63: ...63...