31
FUNCTIONALITY
1-
SWITCHING ON/OFF
:
The control unit is switched on/off by pressing and holding down the
P1
(ON/OFF) button
The OFF status is signalled by the lighting of LED
L5.
2- SAFETY function:
If the temperature detected by the
PROBE
exceeds the value of the
Safety Thermostat,
this forces the activation of the PUMP.
3- ALARM function:
If the temperature detected by the
PROBE
exceeds the value of the
Alarm Thermostat
,
this activates the acoustic and visual signal.
SILENCE
: by pressing any button, the acoustic signal is
deactivated for
5 minutes.
4- NO ICE function:
If the temperature detected by the
PROBE
goes below the value of the
ANTI-FREEZE
Thermostat,
this activates the timed
PUMP
outlet.
The associated LED
L1
is lit and the word
ICE
starts flashing on the
display.
5- PUMP ANTI-LOCKING programme:
In the event of inactivity of the
PUMP
outlet for longer than the
ANTILOCKING Timer,
this activates the outlet of the
PUMP.
The associated LED
L1
is lit and
bLP appears on the display.
6- SECURE TEMP function:
If the device is
OFF
and in the
SAFETY
condition,
the device automatically switches itself to
ON
status.
7- LEVEL SWITCH function:
The closure of the input contact determines the activation of LED
L4
.
8- OUTPUTS function:
PUMP ON:
for a temperature above the PUMP thermostat
temperature
for a temperature above the ALARM thermostat
temperature
Содержание K top
Страница 1: ...INSTALLATION USE AND MAINTENANCE USEFUL ADVICE Heating cooker Heating stove User guide EN...
Страница 2: ...2...
Страница 5: ...5 HEATING COOKERS and HEATING STOVES models K top KP top and models TS top TSP top S R L...
Страница 15: ...15 Top view of heating stove 600 665 622 275 515 170 150...
Страница 49: ...49 Loosen the two hex screws on the inspection vent 1 2...
Страница 50: ...50 Remove the vent as shown in the diagram and remove any deposits under the oven...
Страница 63: ...63...