
6.4 RS-485 connection
The SOLYS is equipped with a 4 wire RS-485 connection with galvanic isolation to the internal electronics and power supply. All
RS-485 wires have an over-voltage protection of 150 V to ground (chassis, VDC ground and VAC protective ground). The RS-485 is
ESD and surge protected (IEC 61000-4-2 / 4-5). The serial protocol, commands and messages are described in appendix A to E.
Both the RS-485 and the sun sensor have a 8 pin connector. Identification of the port is on the labels next to the connectors.
Exchanging the connectors will not work, but will also not cause any permanent damage.
8
wire
Pin Layout
(Sun Tracker)
function
RS-485 connection
7
6
5
4
3
2
1
black
white
brown
grey
yellow
green
blue
red
shield
RS-485 / TXD-
RS-485 / TXD+
RS-485 / ground
RS-485 / RXD-
RS-485 / RXD+
not connected
not connected
not connected
housing
85
Содержание SOLYS Gear Drive
Страница 1: ...SOLYS2 Sun Tracker SOLYS Gear Drive Sun Tracker Instruction Manual...
Страница 2: ...2...
Страница 4: ...4...
Страница 6: ...6...
Страница 10: ...10...
Страница 38: ...Figure 3 12 Mounting the sun sensor M5 locking nut 3x Shoulder washer 6x Compression spring 3x Sun Sensor 38...
Страница 39: ...Figure 3 13 Adjustment of the sun sensor 21 0 5 mm 3x 39...
Страница 61: ...6 Insert the Ethernet cable Contacts on this side 61...
Страница 78: ...78...
Страница 80: ...80...
Страница 86: ...86...
Страница 88: ...88...
Страница 112: ......