3
1.
Unit Description.
Burners ROT-POWER series are designed for solid fuels combustion in the form of
pellets with different degrees of pollution and grain size (according to this specification, point
2). The burner operates automatically and does not require supervision. Rotation of a combus-
tion chamber prevents adhesion of slag to the chamber formed during combustion. The slag
moves forward and exits the combustion chamber due to cyclic rotation. Moreover, no adhe-
sion facilitates the cleaning process of the burner and significantly affects its service life.
Combusted bed is oxygenated over the entire length of the combustion chamber, and further
mixed by the rotating combustion chamber that enhances the combustion process and allows
complete combustion of the supplied fuel.
The burner is designed to work with central heating boilers for solid fuels, as well as
several models of gas or oil boilers with a combustion chamber enabling the collection and
selection of ash.
The burner is an ecological device as it uses fuel from renewable sources. It also fea-
tures a small demand for electricity.
The burner is equipped with a controller which is responsible for an optimal dosing of
fuel in accordance with the parameters set by the user, and variable speed power control. This
controller operates with a room thermostat which helps to maintain the temperature in the
room. The burner's controller is also equipped with temperature sensors of the boiler and
DHW. The controller can be connected to circuit pumps of central heating and DHW.
The burner is equipped with a safety fittings, which in the event of overheating or fail-
ure of the flame in the combustion chamber cut off the fuel supply. A break in electricity sup-
ply automatically turns off the fuel supply, and the amount remaining in the combustion
chamber does not result in damage to equipment and cooperating devices.
The burner should be operated by power from an external storage tank for storing fuel,
using a helical transport system, that is the fuel feeder tray.
The burner should only be supplied by fuel specified in point 2.
Содержание ROT-POWER 10-50 kW
Страница 5: ...5 Fig 1 Block diagram of the burner ...
Страница 9: ...9 Fig 2 Components of the set ...
Страница 22: ...22 Fig 8 Cleaning the tubular blower chamber view 1 ...
Страница 23: ...23 Fig 9 Cleaning the tubular blower chamber view 2 ...
Страница 27: ...27 Fig 11 Lubricating the bearings of the combustion chamber view 1 ...
Страница 28: ...28 Fig 12 Lubricating the bearings of the combustion chamber view 2 ...
Страница 30: ...30 Fig 13 Igniter Replacement ...
Страница 34: ...34 12 2 Electric diagram of the burner Fig 15 Wiring diagram of the burner where ...