16
6.
Starting up
1.
Check the level of fuel tank - refill if necessary.
2.
Fill the fuel feeder (5), until the fuel begins to pour into the burner. To enable this
function, press "MENU" button in the controller, then select "Manual operation" func-
tion and press the knob of this option; from in this sub-menu select "feeder", press the
knob - "OFF" message will change into "ON" - at this point the external fuel feeder
will activate - the filling mode lasts for 2 minutes, if the feeding tube s not filled-up,
the operation must be repeated. At any time you can stop filling pressing the knob.
You may exit the filling mode by pressing "EXIT" button.
3.
All controllers connected to the driver should be set to their maximum values or short-
ed (default setting).
4.
Press "MENU" button, to set the operational parameters of the burner and boiler. All
settings and operating parameters are described in the accompanying user manual of
the controller.
5.
Press the knob of the controller and select "YES" - the controller will be activated.
7.
Operation of the burner in the operational mode.
After completing the steps specified in sec. 6, the burner may operate in its continuous
operation mode. As long as fuel is in the fuel tank and no emergency condition is present,
filling the auger feeder with fuel is not necessary. Set the room thermostat to the desired oper-
ating mode.
After switching the controller, as described in sec. 5 of chapter 6 - the controller enter
standard operation mode. Depending on the set parameters and operation status of the sensors,
the controller will operate in the following modes - displaying appropriate messages.
Содержание ROT-POWER 10-50 kW
Страница 5: ...5 Fig 1 Block diagram of the burner ...
Страница 9: ...9 Fig 2 Components of the set ...
Страница 22: ...22 Fig 8 Cleaning the tubular blower chamber view 1 ...
Страница 23: ...23 Fig 9 Cleaning the tubular blower chamber view 2 ...
Страница 27: ...27 Fig 11 Lubricating the bearings of the combustion chamber view 1 ...
Страница 28: ...28 Fig 12 Lubricating the bearings of the combustion chamber view 2 ...
Страница 30: ...30 Fig 13 Igniter Replacement ...
Страница 34: ...34 12 2 Electric diagram of the burner Fig 15 Wiring diagram of the burner where ...