18
8.
List of common problems.
No. Fault
Reason
Remedy
1.
Burner does not
ignite
Message:
"Ignition failure"
No fuel in the tank
Fill up the tank with fuel
Carry out the procedure of fill-
ing the feeder - Section 6.2
Clear the error by pressing the
knob
Fuel feeding augers are
blocked
Remove the blocking element
Faulty igniter
Contact the customer service of
the Manufacturer
Drives of feeding augers
are damaged
Contact the customer service of
the Manufacturer
Slag in the furnace
Clean the combustion chamber
Photodiode damaged or
dirty
Clean the photodiode
In case of damage, contact the
customer service of the Manu-
facturer
Slag or ash in the combus-
tion chamber of the central
heating boiler - at the level
of the burner combustion
chamber
Clean the central heating boiler
combustion chamber.
2.
Alarm:
"Feeder
maxi-
mum temperature
exceeded"
Excessive temperature rise
on the burner housing,
which results by flame
backfiring from the com-
bustion chamber (default
90
O
C)
The controller automatically
enters the furnace quenching
mode. The alarm may be delet-
ed only by the user.
Insufficient chimney draft.
Verify the value of the chimney
draft and take necessary action
in order to increase it.
Slag or ash in the combus-
tion chamber of the central
heating boiler - at the level
of the burner combustion
chamber
Clean the central heating boiler
combustion chamber.
3.
Alarm:
"Feeder tempera-
ture sensor dam-
aged"
Housing temperature sen-
sor damaged
Contact the customer service of
the Manufacturer
4.
Alarm:
Maximum boiler
temperature
ex-
ceeded
Boiler set temperature is
exceeded.
Wait until the water temp. drops
below the preset temp.
Clear the error by pressing the
knob
Setting of the boiler operat-
ing temperature is too low
Increase the boiler operating
temperature, as specified in the
Содержание ROT-POWER 10-50 kW
Страница 5: ...5 Fig 1 Block diagram of the burner ...
Страница 9: ...9 Fig 2 Components of the set ...
Страница 22: ...22 Fig 8 Cleaning the tubular blower chamber view 1 ...
Страница 23: ...23 Fig 9 Cleaning the tubular blower chamber view 2 ...
Страница 27: ...27 Fig 11 Lubricating the bearings of the combustion chamber view 1 ...
Страница 28: ...28 Fig 12 Lubricating the bearings of the combustion chamber view 2 ...
Страница 30: ...30 Fig 13 Igniter Replacement ...
Страница 34: ...34 12 2 Electric diagram of the burner Fig 15 Wiring diagram of the burner where ...