Unit protection devices
Check List
The following items are required for the installation of the Aeromax Plus Air Source Heat Pump
Product Code
Description
KHP0029
4kW, 6kW & 8kW Installation Pack
KHP0030
12kW Installation Pack
KHP0026
15kW Installation Pack
Pack Contents
2 x 750mm flexible hoses
including 90° elbow,
pre-insulated
1 x System filter
W Plan diverter valve
(heat pump specific)
Anti vibration pads
'MVTIöMMQPSUT
Diagnostic indicator
'MPXTFUUFS
7 day hot water
programmer
Programable room stat
Y'VMMCPSFJTPMBUJOH
valve with lever arm
System Antifreeze / Inhibitor - Clear
Product Code
Description
KHP0023
1 x 25 litre system antifreeze inhibitor - Clear
Introduction
The following check list has been prepared to assist you in
understanding the differences from other types of heating
systems you may have installed and help to understand and
comply with all of the technical details contained within this
document to ensure a successful installation.
System cleaning and Water Characteristics
t
In the case of a new installation, or cleaning the circuit, it is
necessary to perform a preventive cleaning of the
system. In order to guarantee the good operation of the
product,each time you clean the system, replace the water
or add glycol, check that the liquid appears clear, without
visibleimpurities and that the hardness is less than 20°f.
t5PIFMQQSPUFDUUIFIFBUQVNQGSPNBOZIFBUJOH
system contamination; the system filter should be fitted
internally on the return pipe.
Recommended system cleansers and inhibitors are listed
below.
'FSOPY'4ZTUFN$MFBOTFS
'FSOPY)1DDPNCJOFEBOUJGSFF[FBOEJOIJCJUPS
Sentinel
All external connecting pipe work should be suitably
insulated using Armaflex flex or similar
Radiator System Circuit
t"TUIF"FSPNBY1MVTHFOFSBUFTMPXFSUFNQFSBUVSFTUIBOB
conventional boiler the radiators should have been
designed to suit the lower mean temperature.
t5IFCBTJDDPOUSPMTXJUIJOUIFTUBOEBSEJOTUBMMFSTQBDLBOE
the parameters on the heat pump are optimised for use
on radiator systems.
Retrofit Situations
t5IFIFBUFYDIBOHFSTIPVMECFQSPUFDUFEGSPNQBSUJDVMBUF
contaminates in the water circuit. The existing radiator
circuit must be chemically cleaned and thoroughly flushed
before installation when fitting in a retrofit situation.
NOTE
'PSTZTUFNTVTJOHVOEFSøPPSIFBUJOHCPJMFS
back up or clients wishing to alter the operating
parameters of the unit; we recommend the
purchase of our advanced controller. See
manual product code KHP0008
NOTE
It is the installer’s responsibility to ensure
correct sizing and provision of both the
domestic circulating pump & any associated
central heating expansion vessel
Installation Pack
1 x 25 litre clear - system
antifreeze inhibitor
25L Heat Pump
Anti Freeze
Concentrate
Anti vibration pads
Содержание AeroMax Plus KHP0038
Страница 2: ...2...
Страница 16: ...Water connections Typical Schematic for Radiator System 16...
Страница 17: ...Water connections Typical Schematic for Radiator System 17 No 2 port required if using with heat pump NOTE...
Страница 60: ...Spare Part List KHP0041 4kW KHP0038 6kW KHP0039 8kW 60...
Страница 62: ...Spare Part List KHP0040 12kW KHP0042 15kW 62...