Installation
Recommended water diagram
(Fig. 9)
Typical water circuit diagram for Aeromx Plus unit (see fig. 9)
1 Isolating
valves
2 System
filter
3 Expansion vessel with PRV & Gauge (Robokit)*
'MVTI'JMM1PSUT
5 System drain valve (at lowest point of system)*
6 Air purge (at highest points of system)*
7 3-way
valve
8 Hot water cylinder
9 Heating
system
10 Circulating pump with isolating valves*
'MPXNFUFSTFUUFS
*not included in installers pack
*OIJCJUFE
Monopropylene
Glycol
'SFF[JOHUJNF
-4 °C
-9 °C
-15 °C
-23 °C
Correction
'BDUPST
Capacity 0,996 0,991
0,983
0,974
Absorbed power
0,990
0,978
0,964
1,008
Loss of head
1,003
1,010
1,020
1,033
5"#-&5064&'03$"-$6-"5*/(5)&8"5&3$0/5&/5*/5)&4:45&.
Installed Unit
.............
Unit content (*)
l
.............
Pipe content (**)
l
.............
Uses (fan-coil, panels, radiators, etc.) (***)
l
.............
Total content (****)
l
.............
(*) Consult the technical data table.
(**) Consult the pipe water content table.
(***) Consult the manual
'SPNUIFSFMFWBOUNBOVGBDUVSFS
.
(****) The water content of the system must be greater than the minimum value for units without hydronic kit. The
minimum value is necessary to provide optimal comfort.
'VSUIFSEFUBJMFEJOTUBMMBUJPOTDIFNBUJDTBSFBWBJMBCMF
Should you require further technical assistance or additional schematics / wiring diagrams please call your local office –
details on the back page of this manual.
Do not use the heat pump to treat industrial process, swimming pool or sanitary water. In all these cases,
provide an intermediate heat exchanger.
14
9
11
Содержание AeroMax Plus KHP0038
Страница 2: ...2...
Страница 16: ...Water connections Typical Schematic for Radiator System 16...
Страница 17: ...Water connections Typical Schematic for Radiator System 17 No 2 port required if using with heat pump NOTE...
Страница 60: ...Spare Part List KHP0041 4kW KHP0038 6kW KHP0039 8kW 60...
Страница 62: ...Spare Part List KHP0040 12kW KHP0042 15kW 62...