1-4
TOS5051A/5050A
10.Status signals
The tester delivers seven status signals--namely, H.V ON, TEST, PASS, U
FAIL, L FAIL, READY, and PROTECTION--through its 14-pin Amphenol
connector (shared with the remote control signals) on the rear panel. The sig-
nal form is open collector. The tester can deliver a 100 VAC output in response
to one of eight states--namely, H.V ON, TEST, PASS, U FAIL, L FAIL,
READY, PROTECTION, and POWER ON. Used in conjunction with the
remote control function, these status signals will help you to conduct still more
ef
fi
cient automatic labor-saving tests.
11.Compact and light
The tester is compact and light as shown below.
12.Memory backup function
When you turn the tester OFF, the tester stores its existing test state in its non-
volatile memory. When you turn the tester ON the next time, the tester recalls
the stored information and restores the test state that existed when you turned
OFF the power last time.
13.A safer high voltage output terminal
The lead insertion portion of the high voltage output terminal is structured with
a restriction for safer connection.
14.A DANGER lamp
The tester has a large and bright DANGER lamp. This lamp lights when elec-
tric charge is remaining on the output terminal, warning you of a possible elec-
tric shock hazard.
15.Interlock function
The tester has an interlock function that shuts down the output voltage in syn-
chronization with the external device. When this function is activated, the out-
put is shut down and keeps tests from being executed.
The interlock function operates even if there is open-circuit or bad contact in
the signal line, thereby enhancing further the operation safety.
16.Keylock function
The tester has a keylock function to disable all keys (except the START/STOP
keys) to guard against inadvertent key operation by the operator or an unautho-
rized person. This improves the reliability of tests.
17.Switches for safer operation
A rotary switch is used for AC/DC test mode selection and test voltage range
selection. The START switch is of a recessed type. These features, together
with the keylock function, enhance operation reliability and safety.
Model
Overall dimensions
Weight
TOS5051A
320 mm (W)
×
132 mm (H)
×
300 mm (D)
16 kg
TOS5050A
15 kg
Содержание TOS5050A
Страница 34: ...3 10 TOS5051A 5050A...
Страница 106: ...8 6 TOS5051A 5050A...
Страница 110: ...9 4 TOS5051A 5050A...