4- 12
Keysight B1507A User’s Guide, Edition 1
GUI Reference
Capacitance Measurement Software
•
Coss
Creates new settings to measure the characteristics of the output capacitance for
the drain-source voltage.
•
Crss
Creates new settings to measure the characteristics of the reverse transfer
capacitance for the drain-source voltage.
•
Cgs, Cds, Cgd
Creates new settings to measure the characteristics of the gate-source
capacitance, drain-source capacitance, and gate-drain capacitance for the
drain-source voltage in order.
•
Cgs
Creates new settings to measure the characteristics of the gate-source
capacitance for the drain-source voltage.
•
Cds
Creates new settings to measure the characteristics of the drain-source
capacitance for the drain-source voltage.
•
Cgd
Creates new settings to measure the characteristics of the gate-drain capacitance
for the drain-source voltage.
•
Rg
Creates new settings to measure the characteristics of the gate resistance for the
gate-source voltage.
•
Cox
Creates new settings to measure the characteristics of the gate oxide capacitance
for the gate-source voltage.
IGBT
You can select one of the following capacitance and resistance parameter
measurements for “IGBT” device type.
•
Cies, Coes, Cres
Creates new settings to measure the characteristics of the input capacitance,
output capacitance, and reverse transfer capacitance for the collector-emitter
voltage in order.
•
Cies
Содержание B1507A
Страница 1: ...Keysight Technologies B1507A Power Device Capacitance Analyzer User s Guide...
Страница 27: ...1 Introduction...
Страница 59: ...2 Installation...
Страница 79: ...3 How To Perform Measurement...
Страница 109: ...4 GUI Reference...
Страница 189: ......