Assembly
3215.72-01i01 Rev. A
P a g e
|
21
5.2
Installation instructions for the qualified electrician
DANGER!
Danger due to electric shock.
Incorrect installation or damage to the live cables during
installation may result in an electrical hazard and thus in death
or serious injury.
►
Carry out all assembly work only in a de-energized state.
►
The electrical connections may only be carried out by a
trained electrician.
Preparatory activities:
Inspect the KuLi for external mechanical damage before starting
assembly.
Remove all packaging components before starting assembly.
WARNING! The KuLi performs a reference run when the supply voltage is applied. This
results in the risk of crushing in the travel range. The assembly may only be carried out
in a voltage-free state!
Observe the following notes for the electrical installation of
the KuLi:
Power supply and control signals are realized via the following
connection:
5-pin M12 connector (A-coded), see pin assignment
Make sure that the supply lines are not pinched or crushed
The plug has a continuous load capacity of 4A/60V. For a short
time, the current load of the plug may be equal to the peak
current of the KuLi of 10A.
Pin
Name
Description
1
+24VDC
Power supply
2
S1 (RS232 TXD)
Plunger retracted
3
GND
Ground
4
Control
input
(RS232-RXD)
0V = run in
+24V = run out
5
S2
Plunger extended
Содержание KuLi Series