Safety
31 / 144
04/2017
1.5
Scope of delivery
Check the system and all components supplied for any faults
1.5.1 Variant Ecolift for underground installation works
1
Drain body
3
Upper section, with inflow cover
5
Extension section (optional, max. 2 units)
20
Pump unit
26
Motor-driven flap unit
37
Seal
41
Cable duct
42
Opening for pressure pipe
56
Inflow side
57
Outlet side
1.5.2 Variant Ecolift for installation above ground
1
Drain body
16 Connection of the pressure pipe
20 Pump unit
26 Motor-driven flap unit
56 Inflow side
57 Outlet side
1
42
20
26
37
5
37
3
41
56
57
Fig. [4]
56
57
1
20
26
16
Fig. [5]
2
Safety
2.1
Correct use
The backwater pumping station serves as a draining system for wastewater with and without sewage, domestic
and industrial wastewater.
2.2
Staff selection and qualification
Persons who install the backwater pumping station must
– be at least 18 years old.
– have been sufficiently trained and be sufficiently qualified for the respective tasks.
– be familiar with and follow the respective technical rules and safety regulations.
Qualified staff are members of staff who, on the basis of their training and experience as well as their knowledge
of the relevant instructions, valid standards and accident prevention regulations, can carry out the required tasks
and both recognise and avoid any possible hazards.
Work on electrical components may only be carried out by specially trained specialist staff and under adherence
to all the valid accident prevention regulations (UVV).
2.3
Organisational safety measures
The operating and maintenance instructions must always be kept available.
2.4
Risks caused by the product
2.4.1 Risk caused by special location / ambient conditions
Risk caused by toxic and hazardous vapours, gases and substances (e. g. bacteria, viruses). If the backwater
pumping station is located in an inspection chamber, any necessary work must always be done by specialist
staff (see 2.2).
2.4.2 Risk of electric shock when plug has been screwed off
There is a risk of electric shock at the control unit if one of the plugs for power supply to the pumps has been
dismantled. The union nut on the electric plug must be fitted so tightly that it cannot be loosened without a tool
(e.g. by children).
2.4.3 Risk caused by hazardous atmosphere
There is a risk of a hazardous atmosphere occurring during work. Make sure the system is well aerated and
use safety equipment such as e.g. a multi-gas warning device if appropriate.
Содержание Ecolift
Страница 22: ...22 144 DOP Leistungserkl rung 04 2017 6 DOP Leistungserkl rung...
Страница 23: ...DOP Leistungserkl rung 23 144 04 2017...
Страница 46: ...46 144 Declaration of performance 04 2017 6 Declaration of performance...
Страница 47: ...Declaration of performance 47 144 04 2017...
Страница 71: ...D claration de performance 71 144 04 2017 6 D claration de performance...
Страница 94: ...94 144 DoP Dichiarazionediprestazione 04 2017 6 DoP Dichiarazione di prestazione...
Страница 95: ...DoP Dichiarazionediprestazione 95 144 04 2017...
Страница 118: ...118 144 DOP vermogensverklaring 04 2017 6 DOP vermogensverklaring...
Страница 119: ...DOP vermogensverklaring 119 144 04 2017...
Страница 142: ...142 144 DOP Deklaracja w a ciwo ci u ytkowych 04 2017 6 DOP Deklaracja w a ciwo ci u ytkowych...
Страница 143: ...DOP Deklaracja w a ciwo ci u ytkowych 143 144 04 2017...