background image

KERN & Sohn GmbH 

D-72322 Balingen-Frommern 
Postbox 4052 
email: [email protected] 

Phone: 0049-[0]7433- 9933-0
Fax: 0049-[0]7433-9933-149 
Internet: www.kern-sohn.de 

Declarations of conformity 

Declaration of conformity for apparatus with CE mark 

Konformitätserklärung für Geräte mit CE-Zeichen 

Déclaration de conformité pour appareils portant la marque CE 

Declaración de conformidad para aparatos con marca CE 

Dichiarazione di conformità per apparecchi contrassegnati con la marcatura CE 

 

English 

We hereby declare that the product to which this declaration refers conforms to the 
following standards.  

This declaration is only valid with the certificate of conformity by a notified body. 

English 

Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den 
nachstehenden Normen übereinstimmt. 

Diese Erklärung gilt nur in Verbindung mit der 

Konformitätsbescheinigung einer benannten Stelle.

 

Français 

Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente 
déclaration, est conforme aux normes citées ci-après.  

Cette déclaration est valide seulement avec un certificat de conformité d´un 
organisme notifié.

 

Español 

Manifestamos en la presente que el producto al que se refiere esta declaración está de 
acuerdo con las normas siguientes 

Esta declaración solo será válida acompañada del certificado de conformidad de 
una institución nombrada.

 

Italiano 

Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è 
conforme alle norme di seguito citate. 

Questa dichiarazione sarà valida solo se 

accompagnata dal certificato di conformità di un ente riconosciuto. 

 

Weighing Instrument: 

 

KLB-TM, KLB 

 

EU Directive 

Standards 

Approval/ 
Test-certificate N° 

Issued by

 

90/384/EEC  
Non automatic weighing 
Instruments 1), 2) 

EN45501    1),

 

2) 

TCM 128/07 - 4498   2) 
ZR 128/07 - 0051   2)

 

CMI 

 

1) 

applies only to certified balances 
gilt nur für geeichte Waagen 
valable uniquement pour les balances vérifiées 
sólo aplicable a balanzas verficadas 
la dichiarazione vale solo per le bilance omologate 

2) 

valid only for KLB-TM terminals in connection with approved load cells 
nur gültig für KLB-TM Terminals in Verbindung mit zugelassenen Lastzellen 
valable uniquement pour les terminaux KLB-TM en liaison avec des cellules de charge homologuées 
sólo válido para terminales KLB-TM en combinación con células de carga aprobadas 
valido solo per terminali KLB-TM in collegamento con celle di carico approvate 

 
 

Date: 01.02.2007 

                    Signature: 

 

 

 

 

Gottl. KERN & Sohn GmbH 

 

 

 

 

Management 

 

 

Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0,Fax +49-[0]7433/9933-149

 

 

  

KLB-TM-BA-e-0811

 

7

Содержание KLB-TM

Страница 1: ...mbH Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating Manual Display units KERN KLB TM Version 1 1 01 2008 GB KLB T...

Страница 2: ...________________________ 10 6 2 Unpacking ______________________________________________________ 10 6 2 1 Setup ______________________________________________________________ 10 6 2 2 Scope of deliver...

Страница 3: ..._____________________________________________________ 29 8 7 4 Median filter _________________________________________________________ 30 8 8 Parts counting ___________________________________________...

Страница 4: ...Parameter description for configuration _____________________________ 49 13 3 Calling menu for entering parameter of configuration __________________ 50 13 4 Default adjustment parameter P 0 9 CAL ___...

Страница 5: ...power supply Standard Weighing cell connection 4 or 6 wire Linearization 6 points Interface RS232 Appropriate for verification yes Reference quantities at piece counting 10 20 50 freely selectable We...

Страница 6: ...as Produkt auf das sich diese Erkl rung bezieht mit den nachstehenden Normen bereinstimmt Fran ais Nous d clarons avec cela responsabilit que le produit auquel se rapporte la pr sente d claration est...

Страница 7: ...al que se refiere esta declaraci n est de acuerdo con las normas siguientes Esta declaraci n solo ser v lida acompa ada del certificado de conformidad de una instituci n nombrada Italiano Dichiariamo...

Страница 8: ...ystem Impacts and overloading exceeding the stated maximum load max of the weighing plate minus a possibly existing tare load must be strictly avoided Both the weighing plate and the display unit may...

Страница 9: ...ions 4 1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and commissioning even if you are already familiar with KERN balances 4 2 Personnel...

Страница 10: ...h humidity vapours and dust Do not expose the display unit to extreme dampness for longer periods of time Non permitted condensation condensation of air humidity on the appliance may occur if a cold a...

Страница 11: ...lectronic display units the display unit must have reached its operating temperature see warming up time chapter 1 During this warming up time the display unit must be connected to the power supply ma...

Страница 12: ...t by using a recommended calibration weight The weighing value is determined during the configuration of the weighing cell See chpt 13 4 Factory settings Procedure when adjusting Observe stable enviro...

Страница 13: ...s the F key The display unit returns to weighing mode SAuE 0 00 g Message Err 4 appears for a calibration error or incorrect test weight In this case repeat the calibration sequence Keep the test weig...

Страница 14: ...ESC Function key to select operating mode PRINT Printout of the weighed value on an external appliance printer or PC 0 Set weight display at zero TARE Taring The display unit carries out an automatic...

Страница 15: ...weight storage 10 0 Weight display at 0 11 Display value is stable 12 PCS Display operating mode piece counting 13 kg g Display operating mode weighing 14 Low battery level battery charge status or da...

Страница 16: ...Func 4 1 FFun ALL Parameter for selection with F key 4 2 Funi YES Weighing units switch over 4 3 PcS YES Parts counting 4 4 HiLo YES Tolerance weighing 4 5 PrcA YES Percentage weighing by means of we...

Страница 17: ...ing up menu Turn on display unit by pressing the ON OFF key Press the F key and PRINT key simultaneously To go from P1 rEAD to P6 CAL in the menu press the a key repeatedly 8 2 2 Storing jumping back...

Страница 18: ...ard weighing unit Selected weighing unit will be retained even after disconnection from the mains Operation Display Turn on display unit by pressing the ON OFF key 0 00 g Press the F key and PRINT key...

Страница 19: ...ay unit by pressing the ON OFF key 0 000 kg Press F key 1 Funi Press TARE key 0 000 kg To change your selection press the a key 0 000 lb To change your selection press the a key 0 000 N Setting will b...

Страница 20: ...ner Read the weight of the goods on the display 53 25 g The taring process can be repeated any number of times e g when adding several components for a mixture adding The limit is reached when the who...

Страница 21: ...he a key until P4 Func appears P4 Func Press TARE key 4 1 FFun Press TARE key ALL All operating modes enabled in menu 4 2 to 4 9 are callable via the F key Press the a key Funi Weighing Units Press th...

Страница 22: ...Press TARE key 4 1 FFun Press the a key 4 2 Funi Press the a key until the operating mode piece counting appears 4 3 PcS Press the TARE key until active setting appears no deactivated yes activated no...

Страница 23: ...kground lighting is turned off automatically every 20 seconds if no change of display takes place Operation Display Selecting the menu item P5 othr Press TARE key 5 1 bl Press TARE key Auto To change...

Страница 24: ...hting is turned off automatically every 20 seconds if no change of display takes place Operation Display Selecting the menu item P5 othr Press TARE key 5 1 bl Press the a key 5 2 blbA Press TARE key 2...

Страница 25: ...be shut off if no weighing takes place within the next 5 minutes t1 no No shut off of display unit Operation Display Selecting the menu item P5 othr Press TARE key 5 1 bl Repeatedly press the a key un...

Страница 26: ...ation of the battery symbol if the weighing unit is operated without battery or accumulator supply by power pack The kind of supply is shown when the balance is started bAtt SLA nlnnH CHr6 YES nlnnH F...

Страница 27: ...nominal capacity of the batteries reached 8 7 P1 rEAd basic settings 8 7 1 Filter settings This menu item allows the display unit to be set according to specific ambient conditions and measuring purpo...

Страница 28: ...balance evaporating processes When apportioning involves small variations of weight it is advisable to switch off this function Auto Zero no Disconnection of auto zero function Auto Zero YES Auto zer...

Страница 29: ...rage of last tare value Value is displayed showing minus sign when balance is started and as a NET symbol on the display User can turn on automatic tare function via F6 AtAr and this will remain activ...

Страница 30: ...1 rEAd Press TARE key 1 1 Fil Repeatedly press the a key until the following display appears 1 4 Fnnd To change your selection press the TARE key no To change your selection press the a key YES Settin...

Страница 31: ...F key 0 00 g Press F key 1 Funi Press the a key 2 PcS Press TARE key FrEE To set the reference number of items on the display press the a key repeatedly A selection of 10 20 50 or FrEE to be picked at...

Страница 32: ...play and the display unit s display will return to weighing mode 8 9 Percent determination Percent determination allows weight display in percent in relation to a reference weight 8 9 1 Determination...

Страница 33: ...y 0100 00 g Enter the reference weight e g 90 33 g Use the TARE key to select the digit to be changed the a key is used to increase the numerical value active digit flashing 0090 33 g Press PRINT key...

Страница 34: ...tive digit flashing Min 0090 00g Press the PRINT key the lower tolerance limit will be imported To enter the upper tolerance limit e g 110 00 g Use the TARE key to select the digit to be changed the a...

Страница 35: ...ods to be weighed on weighing plate 123 45 g A stable weighing value will start automatic taring The display shows NET 0 00 g Place weight in weighing container net weight of weighed item will be show...

Страница 36: ...hown Operation Display Turn on display unit by pressing the ON OFF key 0 00 g Press F key 1 Funi Repeatedly press the a key until 7 toP appears 7 toP Press TARE key Max 0 00 g Place weight on weighing...

Страница 37: ...0 5 kg on weighing plate 0 500 kg Press print key import to summation memory 0 700 kg To cancel current summation press the Print key again and the following message will appear unLoAd Unload weighin...

Страница 38: ...nsmission modes are available Manually after pressing the PRINT key Continuously according to setting Automatically according to stability display Prompted by external device For remote control comman...

Страница 39: ...he PRINT key 2 1 Pr_n For this press the F key repeatedly until SavE appears on the display Store changes carried out by pressing the PRINT key Meaning of settings noStAb immediate data output even if...

Страница 40: ...tomatically The next weighing value will not be issued unless the weighing value has meanwhile dropped below the entered weighing value Operation Display Selecting the menu item P2 Prnt Press TARE key...

Страница 41: ...a key twice until 2 3 bAud appears on the display 2 3 bAud Press TARE key 9600 To change your selection press the a key 19200 38400 2400 4800 9600 Press the PRINT key the baud rate will be imported 2...

Страница 42: ...Press the PRINT key the selection will be imported 2 3 bAud For this press the F key repeatedly until SavE appears on the display Store changes carried out by pressing the PRINT key Meaning of settin...

Страница 43: ...tandard weighing unit CU1 Turn on continuous transmission in current weighing unit CO1 Turn off continuous transmission in current weighing unit PC Send all implemented instructions Complete each inst...

Страница 44: ...Presign Space if positive negative sign if negative Weight 9 signs right justified Unit 3 signs left justified 9 8 2 Manual output The user may start output by pressing the PRINT key Settings in chap...

Страница 45: ...smission in standard weighing unit CU1 CR LF Turn on continuous transmission in current weighing unit CO1 CR LF Turn off continuous transmission in current weighing unit Data record format 1 2 3 4 5 6...

Страница 46: ...Service maintenance disposal 11 1 Cleaning Before cleaning please disconnect the appliance from the operating voltage Please do not use aggressive cleaning agents solvents or similar agents but a clo...

Страница 47: ...nserted The displayed weight is permanently changing Draught air movement Table floor vibrations Weighing plate has contact with other objects Electromagnetic fields static charging choose different l...

Страница 48: ...e unit The contact tabs for the weighing cell are positioned on the top left hand corner of the board Anschluss Function AGND Dimensions of weighing cell 5 V Supply for weighing cell IN Signal of weig...

Страница 49: ...0 1 Adjustment weight in respect of maximum load P 0 8 St_u Initial weight for adjustment P 0 9 CAL Default adjustment P 0 A Gcor 1 00000 0 90000 1 10000 Factor for gravity constant P 0 b LFt no no ye...

Страница 50: ...usly After the menu was called select P 0 FAct by pressing the a key For navigation around menu refer to chapter 8 2 To call specific parameters press the TARE key To change the parameter press the a...

Страница 51: ...nce this is completed LoAD will appear on the display followed by the weight value of the adjustment weight value of P 0 7 wEi Place the adjustment weight on the weighing plate and press the PRINT key...

Страница 52: ...one DonE appears on the display and subsequently returns to the menu on the display appears 0 L LinE If less than 6 linearization points are necessary press the F button when the message nEHt appears...

Страница 53: ...r supply No No Bat Lo display SLA 6V battery block Bat Lo display appears when voltage drops below 5 7 V nimh 6 x 1 2V battery block type AA Bat Lo display appears when voltage drops below 7 2 V Atten...