Wirnet iBTS
Document title : Installation and
Maintenance Manual
Version : 2.0
Author : SNI
Date : 04/12/2018
Classification
This document is the strict property of Kerlink and shall not be either copied nor sent without express
written authorization of Kerlink
Internal Use
Kerlink m2m technologies reserved rights
Confidential
Kerlink – 1 rue Jacqueline Auriol – 35235 THORIGNÉ-FOUILLARD
Page 33 / 221
Strict confidential
1.3.2
Stickers
The Wirnet iBTS Compact has two stickers placed inside and outside the casing:
-
A sticker on the bottom of the Wirnet iBTS Compact cabinet including serial number,
regulatory markings and electrical information.
-
A sticker outside the cabinet including regulatory marking, logo and sentences
depending on the countries (FCC, IC, ANATEL, etc …).
The placement of the stickers is described on Figure 9.
1.4
Block Diagram
1.4.1
Common functionalities
The following figure describes the hardware architecture and basic principles that are
common to the many Wirnet iBTS versions. In this particular case, we consider a
configuration with one “CPU module”, one “WAN module” (or “Dual WAN module”) and one
“LoRa Module”.
Figure 12: Common Wirnet iBTS block diagram
The Wirnet iBTS is power supplied by a PoE injector through the RJ45 cable.
The RJ45 cable is introduced into the enclosure through the M25 cable gland and connected
to the RJ45 connector of the CPU module.
An alternate option of power supply consists in using an auxiliary power supply (11V-55V DC)
and connects it to the Euroblock connector of the CPU module.