The indoor installation is composed of:
A main electrical board including:
o
a circuit breaker
o
a surge protection type 1
o
a connection to “earth”
The outdoor installation is composed of:
A tower, mast or pole that must be connected to “earth”.
The Wirnet iBTS and its mounting kit.
The mounting kit must be connected to earth.
The antennas (LoRa, LTE, GNSS) with their RF coaxial surge protections (see
§1.8.5.1) connected to “earth”.
The PoE injector (see §1.6.1.6 and § 1.6.1.7)
An Ethernet surge protection, connected to “earth” (see §1.8.5.5.)
A lighting rod with a down conductor to earth is still strongly recommended for this kind of
applications to avoid direct impacts on the aerials.
Figure 160 : Installation with recommended lighting protections / Outdoor PoE injector