![KEPCO KLR SERIES Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/kepco/klr-series/klr-series_developers-manual_1956489064.webp)
5-2
KLR-DEV 060713
Measure Current and
Voltage Output Values
Kpklr_MeasVoltCurr
Measures the values of output (voltage and current).
SETTING AND MONITORING OUTPUT FUNCTIONS (CONTINUED)
Get Source Mode
Kpklr_GetSourceMode
Gets the operating mode of the power supply.
Output On/Off
Kpklr_OutputOnOff
Sets the output on or off.
Get Output Status
Kpklr_getOutputState
Returns the output status (on or off).
UTILITY FUNCTIONS
Relay Mode
Kpklr_GetRelayMode
Gets operating mode of instrument relay. 0 = Fault (factory default),
1 = Manual, 2 = List Program
Get Relay Status
Kpklr_GetRelayStatus
Gets on/off status of instrument relay.
Set Relay Status
Kpklr_SetRelayStatus
Sets relay on (energized) or off (de-energized) if Relay Mode is set to
Manual (1).
Set/reset Front Panel
Lock
Kpklr_SetResetKeyblock
Sets or resets front panel controls lockout.
Front Panel Lock Status
Kpklr_KeybLockStat
Gets status of front panel lockout
Revision Query
Kpklr_RevisionQuery
Returns the revision numbers of the instrument driver and instrument
firmware version from the *idn? query. This instrument driver's Revi-
sion Number is "Rev 1.0, 9/99, CVI 5.1" and the KLR firmware version
is Firmware Version "1.0". This data is necessary when requesting
technical support.
Model Query
Kpklr_ModelQuery
Return the model number of the KLR power supply.
Serial Number Query
Kpklr_SerialnQuery
Returns the serial number of the KLR power supply. The serial num-
ber is extracted from the answer to the *idn? query.
Query SCPI Version
Kpklr_GetScpiVersion
Returns the power supply answer to the Query SCPI Version com-
mand. Checks the Standard Commands for Programmable Instru-
ments (SCPI) language version.
Self-Test
Kpklr_selfTest
Runs the instrument's self test routine and returns the test result(s).
Error-Query
Kpklr_errorQuery
Reads an error code from the instrument's error queue.
Error Message
Kpklr_errorMessage
Takes the Status Code returned by the instrument driver functions,
interprets it and returns it as a user readable string.
Get System Setting
Kpklr_SYST_Set
Gets System Settings
Get Trigger Value
Kpklr_GetTrigValue
Gets the trigger voltage or the trigger current level, depending on the
switch position.
Set Trigger Value
Kpklr_SetTrigValue
Sets the trigger voltage or trigger current level, depending on the
switch position.
Trigger
Kpklr_Trig
Triggers the instrument once. The output will go to the trigger voltage
and current values.
LIMIT MODEL FUNCTIONS
Set Max Voltage/Current
Kpklr_SetMaxLimValue
Sets limit to maximum voltage/current.
Get Max Voltage/Current
Kpklr_GetMaxLimValue
Gets maximum voltage/current limit values.
Security Code
Kpklr_CalCode
Allows the user to change the password to prevent accidental or
unauthorized calibrations of the instrument. The password is stored in
non-volatile memory, and does not change when power has been off
or after a reset. To change the password, the instrument must already
be in calibration status, ensuring that the user knows the current pass-
word. If the password is lost, call the factory for support.
Calibration Dump
Kpklr_CalDump
Instrument sends calibration data in Intel Hex format.
TABLE 5-1. KLR VXI
PLUG&PLAY
DRIVER FUNCTIONS (CONTINUED)
Purpose
Function Name
Description
Содержание KLR SERIES
Страница 2: ......
Страница 10: ......
Страница 42: ......
Страница 58: ...4 16 KLR DEV 060713 FIGURE 4 10 FUNCTION GENERATOR PANEL FIGURE 4 11 CONFIGURE User Sequence vi BLOCK DIAGRAM ...
Страница 59: ......
Страница 60: ......
Страница 61: ...FIGURE 4 13 FUNCTION GE ...
Страница 62: ......
Страница 86: ......
Страница 90: ......