B-4
KLR-DEV 060713
B.8
INITiate:CONTinuous QUERY
INIT:CONT?
Syntax
:
Short Form: INIT:CONT?
Long Form: INITiate:CONTinuous?
Return Value: 1 or 0 (1 = on, 0 = off)
Description:
Determines whether continuous triggers are enabled or disabled.
Power supply returns value of
INIT:CONT flag: “1” = continuous triggers are enabled (INIT:CONT ON); “0” = continuous triggers dis-
abled (INIT:CONT OFF). (See example, Figure B-1.)
B.9
[SOURce:]LIST:CLEar COMMAND
LIST:CLE
Syntax:
Short Form: LIST:CLE
Long Form: LIST:CLEar>
Description:
Clears all list entries by setting all pointers to 0.
Also sets LIST:DIR to UP. Related Commands: All
LIST commands (See example, Figure B-2.)
B.10 [SOURce:]LIST:CONTrol COMMAND
LIST:CONT
Syntax:
Short Form: LIST:CONT {1 | 0} (1 = on, 0 = off)
Long Form: LIST:CONTrol>{1 | 0} (1 = on, 0 = off)
Description:
If relay control set to LIST, allows user to energize (1 or on) or de-energize (0 or off) internal
relay using LIST commands.
A LIST:CONT value (0 or 1) must be entered, regardless of relay con-
trol setting selected. Related Commands: LIST:CONT?.
B.11
[SOURce:]LIST:CONTrol? QUERY
LIST:CONT?
Syntax:
Short Form: LIST:CONT?
Long Form: LIST:CONTrol?
return value = 0 (off, de-energized) or 1 (on, energized)
Description:
Identifies whether internal relay is energized (1) or de-energized (0).
Related Commands:
LIST:CONT.
B.12 [SOURce:]LIST:CONTrol:POINts?
QUERY
LIST:CONT:POIN?
Syntax:
Short Form: LIST:CONT:POIN?
Long Form: LIST:CONTrol:POINts?
Return Value: <int_value>
Description:
Identifies number of control points in the list.
If this command returns 0, no control points were
provided: the list will not execute and error, -226,“Lists not same length” will be returned.
B.13 [SOURce:]LIST:COUNt COMMAND
LIST:COUN
Syntax:
Short Form: LIST:COUN <int_value 0 to 65535>Long Form: LIST:COUNt> <int_value 0 to 65535>
Description:
Establishes how many times the list is executed.
Allows user to establish how many times the list
is executed. The order (beginning to end or end to beginning) is determined by LIST:DIR. For
LIST:COUN 0, the unit will execute the sequence indefinitely until a VOLT:MODE FIXED command is
received. Related Commands: LIST:DIR. (See example, Figure B-2.)
B.14 [SOURce:]LIST:COUNt?
QUERY
LIST:COUN?
Syntax:
Short Form: LIST:COUNT?
Long Form: LIST:COUNt?
Return Value: <int_value>
Description:
Identifies how many times the list will be executed.
Returns value set by LIST:COUN command.
(See example, Figure B-2.)
B.15 [SOURce:]LIST:COUNt:SKIP COMMAND
LIST:COUN:SKIP
Syntax:
Short Form: LIST:COUN:SKIP nn
Long Form: LIST:COUNt:SKIP nn
nn = 0 to 250
Description:
Allows beginning steps of list-generated waveform to be run once, then ignored.
When a list is to be repeated using LIST:COUNT, this command allows the user to skip the first nn
steps once the full set has been executed. After the first iteration (which executes all steps), the first
nn steps are skipped. The LIST:COUN:SKIP command allows the user to precondition a list-generated
waveform by setting unique conditions at the beginning that are not repeated for the rest of the repeti-
tions. LIST:CLEar sets nn to 0. Only works in LIST:DIR UP mode, if LIST:DIR DOWN is issued, this
command has no effect. Related Commands: LIST:COUN, LIST:COUN:SKIP?, LIST:DIR, LIST:CLE.
(See example, Figure B-2.)
Содержание KLR SERIES
Страница 2: ......
Страница 10: ......
Страница 42: ......
Страница 58: ...4 16 KLR DEV 060713 FIGURE 4 10 FUNCTION GENERATOR PANEL FIGURE 4 11 CONFIGURE User Sequence vi BLOCK DIAGRAM ...
Страница 59: ......
Страница 60: ......
Страница 61: ...FIGURE 4 13 FUNCTION GE ...
Страница 62: ......
Страница 86: ......
Страница 90: ......