![KEPCO KLR SERIES Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/kepco/klr-series/klr-series_developers-manual_1956489044.webp)
4-2
KLR-DEV 060713
TABLE 4-1. KLR LABVIEW G DRIVER FUNCTIONS
Function Name
Purpose
KepcoDCPWR initialize with options
Makes Visa Connection. Creates Open handle
Provides ability to issue Reset and parse IDN
KepcoDCPWR initialize
Makes Visa Connections, No Reset, IDN is parsed and Kepco
model is properly identified.
Kepco Serial initialize with options
Makes Visa Connection. Creates Open handle
Provides ability to issue Reset and parse IDN
KepcoDCPWR close
Closes the driver, freeing resources
Recognize Model
Sends *IDN? And verifies KEPCO string returned
KepcoDCPWR IDN parser
Parse the IDN string – determining model
KepcoDCPWR Revision Query
Uses IDN parser to determine firmware revision
KepcoDCPWR Reset
Sends *RST to Power supply, set output off, volt=0, curr min,
over voltage and over current to max values
KepcoDCPWR Reset with Defaults
Supplied for compatibility purposes uses above
KepcoDCPWR Self-test
Sends *TST? To unit and returns result- o= all okay.
Output Control functions
KepcoDCPWR Configure Voltage Level
Set voltage output setting to a specific value
KepcoDCPWR Configure Current Level
Sets current output setting to a specific level
KepcoDCPWR Query Voltage Level
Queries unit and returns voltage level setting
KepcoDCPWR Query Current Level
Queries unit and returns Current level setting
KepcoDCPWR Configure Voltage Limit
Set virtual voltage setting to a specific value
KepcoDCPWR Configure Current Limit
Sets virtual current setting to a specific level
KepcoDCPWR Query Voltage Limit
Queries unit and returns limit model voltage level setting
KepcoDCPWR Query Current Limit
Queries unit and returns limit model Current setting
KepcoDCPWR Configure OVP
Set over voltage setting to a specific value
KepcoDCPWR Configure OCP
Sets Over current setting to a specific level
KepcoDCPWR Configure Output State
Sets output on or off
KepcoDCPWR Query Output State
Returns Output on(1) or off(0).
Measurement
KepcoDCPWR Measure [MSR]
Returns the voltage read back 9 default or Current read back
value from KLR.
List Functions (supported in standalone configurations only)
KepcoDCPWR Configure Current Mode
Sets unit to List or Fixed mode of operation. Fixed operation is
default
KepcoDCPWR Configure Voltage Mode
Sets unit to List or Fixed mode of operation. Fixed operation is
default
KepcoDCPWR Configure User Sequence
Initializes list from an array of either voltage and dwell or Cur-
rent and dwell to execute the list a number of times.
Содержание KLR SERIES
Страница 2: ......
Страница 10: ......
Страница 42: ......
Страница 58: ...4 16 KLR DEV 060713 FIGURE 4 10 FUNCTION GENERATOR PANEL FIGURE 4 11 CONFIGURE User Sequence vi BLOCK DIAGRAM ...
Страница 59: ......
Страница 60: ......
Страница 61: ...FIGURE 4 13 FUNCTION GE ...
Страница 62: ......
Страница 86: ......
Страница 90: ......