B-10
KLR-DEV 060713
FIGURE B-3. PROGRAMMING LIMIT MODELS
B.39 [SOURce:]CURRent:LIMit:HIGH? QUERY
CURR:LIM:HIGH?
Syntax:
Short Form: [SOUR:]CURR:LIM:HIGH? (MIN | MAX)
Long Form: [SOURce:]CURRent:LIMit:HIGH? (MIN | MAX)
Return Value:<exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Returns value representing Limit Model current limit.
CURR:LIM:HIGH?
returns the current limit
programmed by CURR:LIM:HIGH. CURR:LIM:HIGH? MAX returns the rated maximum programmable
current for that model (e.g., 32 (Amperes) for KLR 75-32. CURR:LIM:HIGH? MIN returns the minimum
allowable current that can be programmed.
Related Commands: CURR:LIM:HIGH, CURR. (See example, Figure B-3.)
B.40 [SOURce:]CURRent:MODE COMMAND
CURR:MODE
Syntax:
Short Form: [SOUR:]CURR:MODE (FIX | LIST | TRAN,n,A]
Long Form: [SOURce:]CURRent:MODE (FIXed | LIST | TRANsient,n,A]
n = <value> = time between 0.04 to 655.36 in seconds
A = <value> = Current level in Amperes
Description:
Allows the user to execute or stop a list, or to execute a transient.
The default mode is FIX: the
power supply executes commands normally, and LIST commands can be issued to establish the
parameters and sequence of a list.
Two milliseconds after CURR:MODE LIST is issued, a list is executed (See LIST commands and
Figure B-2). While the list is being executed, LIST commands are not accepted and will produce a
command error. The 4- character front panel display shows
dLST
when a list is executing.
Issuing CURR:MODE FIX while the list is running will stop the execution of the list and return power
supply to settings in effect prior to running the list. If the list runs to completion, the settings of the last
step of the list will be in effect.
CURR:MODE TRAN,<n>,<A> [R option (RODC installed) models only.] Two milliseconds after issu-
ing this command the KLR output current changes to the specified current level <A> for the period of
time <n> specified. At the end of time <n>, the current is returned to the previously established value.
The status display shows
dLST
during the execution of the transient. If any of the variables are incor-
rect, the transient is not generated, and an appropriate error message is generated (see Table B-5). If
CURR:MODE TRAN command is issued to a non-R option unit, error message -113, “undefined
header” is posted to the error queue. If current value is less than model minimum, the minimum value
is entered and no error is generated.
Related Commands: LIST commands. (See example, Figure B-2.)
B.41 [SOURce:]CURRent:MODE? QUERY
CURR:MODE?
Syntax:
Short Form: [SOUR:]CURR:MODE?
Long Form: [SOURce:]CURRent:MODE?
Return value:
FIXED or LIST or TRAN
Description:
Identifies active voltage mode.
Returns LIST while list is being executed. TRAN (transient) is not
supported at this time, contact Kepco for more information. Returns FIXED while in fixed (default)
mode of operation. Related Commands: LIST commands. (See example, Figure B-2.)
NOTE: The following example assumes KLR 75-32 with limit model set for 75V, 16A and output operat-
ing in voltage stabilization mode.
SYST:PASS:CEN 7533
Enables access to the protected commands. NOTE: Password
shown is factory default value for KLR 75-32; values will vary for
other models (see Table B-4) and can be altered by user.
VOLT:LIM:HIGH?
Returns 7.5E1 (75V, limit model voltage rating).
VOLT:LIM:HIGH 70
Programs limit model voltage to 70V.
VOLT:LIM:HIGH?
Returns 7.0E1 (70V, new limit model voltage rating).
CURR:LIM:HIGH?
Returns 1.6E1 (16A, limit model current rating).
CURR:LIM:HIGH 30
Programs limit model current to 30A.
CURR:LIM:HIGH?
Returns 3E1 (30A, limit model current rating).
VOLT:LIM:HIGH 33
Programs limit model voltage to 30A. Limit model settings are now
programmed to 33V and 30A.
Содержание KLR SERIES
Страница 2: ......
Страница 10: ......
Страница 42: ......
Страница 58: ...4 16 KLR DEV 060713 FIGURE 4 10 FUNCTION GENERATOR PANEL FIGURE 4 11 CONFIGURE User Sequence vi BLOCK DIAGRAM ...
Страница 59: ......
Страница 60: ......
Страница 61: ...FIGURE 4 13 FUNCTION GE ...
Страница 62: ......
Страница 86: ......
Страница 90: ......