ATE-DMG 020613
3-29
3.7.6
PROGRAM MESSAGE SYNTAX SUMMARY
• Common commands begin with an asterisk (*).
• Queries end with a question mark (?).
• Program messages consist of a root keyword and, in some cases, one or more message
units separated by a colon (:) followed by a message terminator. Several message units
of a program message may be separated by a semicolon (;) without repeating the root
keyword.
• If a program message has more than one message unit, then a colon (:) must precede
the next keyword in order to set the parser back to the root (otherwise the next keyword
will be taken as a subunit of the previous message unit).
e.g., the command
meas:volt?;curr?
will read output voltage and output current
since both
volt?
and
curr?
are interpreted as subunits of the
meas
command.
• Several commands may be sent as one message; a line feed terminates the message.
Commands sent together are separated by a semicolon (;). The first command in a mes-
sage starts at the root, therefor a colon (:) at the beginning is not mandatory.
e.g., the command
meas:volt?;:curr?
will read output voltage and programmed cur-
rent since the colon preceding
curr?
indicates that
curr?
is not part of the
meas
com-
mand and starts at the root.
• UPPER case letters in mnemonics are mandatory (short form). Lower case letters may
either be omitted, or must be specified completely (long form)
e.g.,
INSTrument
(long form) has the same effect as
INST
(short form).
• Commands/queries may be given in upper/lower case (long form)
e.g.,
SoUrCe
is allowed.
• Text shown between brackets [ ] is optional.
e.g.,
:[SOUR]VOLT:[LEV] TRIG
has the same effect as
:VOLT TRIG
3.7.7
SCPI PROGRAM EXAMPLES
Refer to Appendix B, Figures B-1 through B-8 for examples illustrating the use of SCPI com-
mands.
Figure 3-10 is an example of a program using SCPI commands to program the ATE-DMG
Power Supply. The program illustrated is for a configuration using an IBM PC or compatible with
a National Instruments GPIB interface card. (It will be necessary to consult the manufacturer’s
data to achieve comparable functions with an interface card from a different manufacturer.) This
program sets output voltage (Voltage mode) or voltage limit (Current mode) to 5V, and current
limit (Voltage mode) or output current (Current mode) to 1A, then reads the measured (actual)
voltage and current, then prints the measurements.
Содержание ATE 100-10DMG
Страница 2: ......
Страница 6: ......
Страница 14: ......
Страница 15: ...ATE DMG020613 ix FIGURE 1 1 ATE DMG SERIES PROGRAMMABLE POWER SUPPLY...
Страница 16: ...ix Blank x ATE DMG020613...
Страница 24: ...1 8 ATE DMG OPER 020613 FIGURE 1 2 MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 26: ...2 2 ATE DMG 020613 FIGURE 2 1 ATE DMG FULL RACK SERIES FRONT PANEL...
Страница 34: ......
Страница 74: ......
Страница 98: ......