FIGURE 2-3. LOCATION OF INTERNAL CONTROLS
TABLE 2-3. INTERNAL CONTROLS AND THEIR FUNCTIONS
REFERENCE
DESIGNATION
CONTROL
PURPOSE
CAUTION:
Adjustment of any internal control will affect digital control of the output voltage
and invalidate factory calibration (refer Calibration, Section 4).
R18
lo MAX
Maximum Output Current
R27
Eo LAG
Voltage Channel Stability Control
R30
Eo ZERO
Voltage Channel Zero Control
R35
lo ZERo
Current Channel Zero Control
R68
PREAMP CURRENT ZERO
Offset Zero Control for CURRENT PREAMP
R67
PREAMP VOLTAGE ZERO
Offset Zero Control for VOLTAGE PREAMP