ATE-DMG 020613
3-15
value, or enter new value (between 0.01 and 300 seconds) and press
ENTER
to accept new
value or press
CLEAR
to exit without changing value. The unit returns to command entry status
. Refer to PAR. 3.4.15.1.2 if accuracy of time values is important.
3.4.15.1.2 TIME INTERVAL ACCURACY
The accuracy of the time interval is ±2.5%. For setting time intervals from 0.01 to 2.50 seconds,
the unit will accept times that are accurate to 0.01 second. (e.g., 2.49 seconds). For setting time
intervals between 2.50 seconds and 50 seconds the second decimal place is ignored, providing
accuracy to 0.1 second (e.g., entering 2.79 is accepted as 2.7). When the time interval is greater
than 50 seconds, the decimal is ignored and the time increment is in full seconds.
3.4.15.1.3 DISPLAY PROGRAM OPTION
When running a program, if the Display Program option is on, the LCD will display the mode
(
Loc/Rem RunPg CV/CC
) and active voltage and current values (programmed). if the Display
Program option is turned off, the LCD displays the message
**PROGRAM RUNNING**
. Since
the accuracy of the time intervals is affected by whether this option is on or off, it is recom-
mended that this option be turned off when accurate time intervals are important; otherwise this
option should be turned on.
With the power supply in command entry status , press
MENU
key 11 times. The LCD top line
reads
DispPrg
ON
or
OFF
. Choosing ON displays the programmed values, choosing OFF
displays the **PROGRAM RUNNING** message. Press
ENTER
or
CLEAR
to exit without
changing setting. Enter
0
(OFF) or
1
(ON) and press
ENTER
or
CLEAR
to menu.
3.4.15.2 RUNNING A PROGRAM
With the power supply in command entry status , press
RUN
key. The LCD bottom line indi-
cates the start address of the program. Press
ENTER
key to run the program starting with that
address. To change the starting address, enter new value and press
ENTER
to run the pro-
gram. Press
CLEAR
to exit without running the program
3.4.15.3 STEPPING THROUGH A PROGRAM
The STEP function is useful for examining a program that has just been created or edited before
running in real-time. With the power supply in command entry status , press
STEP
key. The
LCD bottom line indicates the start address of the program; press
ENTER
to begin stepping at
that address. To change the starting address, enter new value and press
ENTER
to begin step-
ping at the new address, press
CLEAR
to exit without stepping through the program.
The LCD top line shows
LOC
to indicate local mode,
aa
"
bb
where aa is the memory location
just executed, bb is the NEXT STEP location, and shows
CV
(constant voltage) or
CC
(constant
current) to indicate the actual operating mode. The LCD bottom line shows the output voltage
and current measurements for the location just executed, and indicates command status.
Press
STEP
to execute location bb. The LCD will again display the location just executed, volt-
age and current measurements, and the NEXT STEP location. Continue to press
STEP
to exe-
cute the program one step at a time, or press
CLEAR
to exit Step function.
3.4.15.4 CYCLING A PROGRAM
To cycle a program, modify the program (see PAR. ) and go to the last memory location to be
executed and set the NEXT STEP address to the Starting address, causing the program to loop
and repeat indefinitely. For example, if the last location is 14, and the starting location is 05,
Содержание ATE 100-10DMG
Страница 2: ......
Страница 6: ......
Страница 14: ......
Страница 15: ...ATE DMG020613 ix FIGURE 1 1 ATE DMG SERIES PROGRAMMABLE POWER SUPPLY...
Страница 16: ...ix Blank x ATE DMG020613...
Страница 24: ...1 8 ATE DMG OPER 020613 FIGURE 1 2 MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 26: ...2 2 ATE DMG 020613 FIGURE 2 1 ATE DMG FULL RACK SERIES FRONT PANEL...
Страница 34: ......
Страница 74: ......
Страница 98: ......