5 ANALOG function
126
Emergency ID (Analog) (FleetSync (Fleet/ID))
Type
‘
■
Standard model
■
Basic model
Description
Specifies the destination transceiver’s FleetSync Fleet Number and ID used during emergency call
transmissions.
The transceiver encodes the FleetSync Emergency Status "99" with the FleetSync ID code during emergency
call transmissions.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Emergency ID
,
FleetSync (Fleet, ID)
:
Edit > Emergency Information > Profiles > Page 1 > Emergency ID (Analog) > FleetSync
Emergency ID
,
ID Type
: Edit > Emergency Information > Profiles > Page 1 > Emergency ID (Analog)
Emergency ID (Analog) (ID Type)
Type
‘
■
Standard model
■
Basic model
Description
Emergency ID (Analog) (ID Type)
is used to select the signaling type (DTMF, FleetSync, MDC-1200) and
the ID code to be sent each time the transceiver goes to automatic transmission in Emergency mode on
Analog Conventional Channel.
Busy Channel Lockout
Configuration
Description
None
The transceiver does not transmit its identification. No ID is transmitted in
Emergency Mode.
Transmission/receiving is based on QT/DQT setting of particular channel setting.
DTMF
The transceiver transmits the Emergency DTMF ID. The transceiver encodes an
Emergency DTMF ID with the Emergency transmission. The "Emergency DTMF
ID" must be programmed in the Emergency fields using the KPG-D6/D6N.
DTMF ID can be set for each emergency activation factor (
Emergency Button
,
Lone Worker
).
FleetSync/MDC-1200
In FleetSync, the transceiver transmits the Emergency Fleet, the Emergency ID,
and the Status "99". The transceiver encodes a FleetSync Emergency Status "99"
with the Unit ID. The destination Fleet Number and ID Number must be
programmed in the Emergency fields using the KPG-D6/D6N.
In MDC-1200, the transceiver transmits the Emergency Alarm packet of
MDC-1200 with own ID. After it turns to Emergency mode, the transceiver
transmits the Emergency PTT ID packet with MDC-1200 own ID.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Emergency ID
,
ID Type
: Edit > Emergency Information > Profiles > Page 1 > Emergency ID (Analog)
Emergency Alarm (MDC-1200)
: Edit > Emergency Information > General
Emergency Button
: Edit > Emergency Information > Profiles > Page 1 > Emergency ID (Analog) > DTMF ID
Lone Worker
: Edit > Emergency Information > Profiles > Page 1 > Emergency ID (Analog) > DTMF ID
FleetSync (Fleet, ID)
: Edit > Emergency Information > Profiles > Page 1 > Emergency ID (Analog) > FleetSync
Automatically Transmitting and Receiving in Emergency Mode (
Emergency Microphone Sense
)
Type
‘
■
Standard model
■
Basic model
Description
The description of this feature is the same as the feature with the same name in the DMR function.
Operating the transceiver
-
-
Note
-
Configuration using FPU
-
Emergency Mode (Placing the Transceiver in Emergency Mode Using the Lone Worker Function)
Type
‘
■
Standard model
■
Basic model
Description
The description of this feature is the same as the feature with the same name in the DMR function.
Operating the transceiver
-
-
Note
-