3 DMR function
11
Indication and Display (
Optional Signaling LED
)
Type
‘
■
Standard model
■
Basic model
Description
Optional Signaling LED
is the function to make the LED flash yellow when the Optional Signaling matches.
A user can notice by the LED that the transceiver is receiving a call.
If the matching state of Optional Signaling is disabled when the buttons on the transceiver are pressed, or when
the time configured in
Auto Reset Timer
elapses, the LED is turned off.
However, if
Selective Call Alert LED
is enabled, the LED flashes according to the configuration in Selective Call
Alert LED even if
Optional Signaling LED
is enabled.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Optional Signaling LED
: Edit > DMR > Conventional 3
Configuring the Alert Tone Pattern (
Special Alert Tone
)
Type
‘
■
Standard model
■
Basic model
Description
This tone sounds from the transceiver when the transceiver receives various types of calls, Status Message, or
Short Message. A maximum of 8 types of tones can be arbitrarily configured or changed.
An Alert Tone sounds from the transceiver such as when the transceiver receives a call using an Individual Call
or a Group Call, a Status Message, or a Short Message and notifies the user of the reception.
The Alert Tone pattern can be configured by selecting from 8 types of tones configured in
Special Alert Tone
.
Alert Tone is the alert tone pattern when receiving a call with the optional signaling.
An Alert Tone that is suitable for a user
’
s environment can be selected.
Alert Tone can be used to select from 8 patterns of Alert Tones. An Alert Tone pattern consists of 16 tones.
Alert Tone can be configured by using KPG-D6/ D6N.
The following table shows the configuration items.
Alert Tone
Configuration
Description
Cycle
This function can be used to configure the number of times for the Alert Tone that
sounds from the transceiver. A number from 1 to 255 can be configured.
The Alert Tone sounds from the transceiver until it is manually stopped if
“
Infinite
”
is configured.
If it is intended for the Alert Tone to sound multiple times, the Alert Tone does not
sound from the transceiver while the transceiver unmutes the speaker. Or, if the
matching state of Optional Signaling is reset, Alert Tone will also be disabled.
Interval Time
This function can be used to configure the timing to repeat the Alert Tone that
sounds from the transceiver.
A time between 0 s and 255 s can be configured in steps of 1 s.
Frequency
The tone frequency can be configured.
A frequency between 400 Hz and 2500 Hz can be configured in steps of 10 Hz.
Gap can be configured if
“
None
”
is selected.
Length
The tone length can be configured.
A tone length between 0 ms and 2500 ms can be configured in steps of 10 ms.
No tone sounds if 0 ms is configured.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Cycle
,
Interval Time
,
Frequency
,
Length
:
Edit > Special Alert Tone