4 NXDN function
88
ID Sent When Emergency Mode is Activated (
Emergency ID (NXDN Conventional) (ID Type)
)
Type
‘
■
Standard model
■
Basic model
Description
The
Emergency ID
can be sent each time the transceiver starts automatic transmission and reception in
Emergency Mode.
Emergency ID Type is the type of NXDN ID used in Emergency Mode.
Emergency NXDN ID is the NXDN ID used for transmission and reception in Emergency Mode.
Operating the transceiver
-
-
Note
-
Configuration using FPU
ID Type
: Edit > Emergency Information > Profiles > Page 1 > Emergency ID (NXDN Conventional)
ID Sent When Emergency Mode is Activated (
Emergency ID (NXDN Conventional) (NXDN ID)
)
Type
‘
■
Standard model
■
Basic model
Description
The
Emergency ID
can be sent each time the transceiver starts automatic transmission and reception in
Emergency Mode.
Emergency ID Type is the type of NXDN ID used in Emergency Mode.
Emergency NXDN ID is the NXDN ID used for transmission and reception in Emergency Mode.
Operating the transceiver
-
-
Note
-
Configuration using FPU
NXDN ID
: Edit > Emergency Information > Profiles > Page 1 > Emergency ID (NXDN Conventional)
Automatically Transmitting and Receiving in Emergency Mode (
Emergency Microphone Sense
)
Type
‘
■
Standard model
■
Basic model
Description
Emergency Microphone Sense
is the function used to adjust the microphone input sensitivity in Emergency
Mode.
In
Emergency Microphone Sense
, the microphone sensitivity can be configured within the following range:
6 dB, 4 dB, 2 dB, 0 dB, -2 dB, -4 dB, -6 dB, -8 dB, -10 dB, -12 dB, -14 dB, -16 dB, -18 dB, -20 dB
The appropriate level of microphone sensitivity for normal operation is 0 dB. Based on this level, the parameter
of the microphone sensitivity can be configured.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Emergency Microphone Sense
: Edit > Emergency Information > General
Emergency Mode (Placing the Transceiver in Emergency Mode Using the Lone Worker Function)
Type
‘
■
Standard model
■
Basic model
Description
Lone Worker is the function that automatically places the transceiver in Emergency Mode if the transceiver is not
operated for a certain period of time.
If the transceiver is placed in Lone Worker Mode while the user has a task at a dangerous place, for instance,
the transceiver automatically enters Emergency Mode and notifies a base station of the emergency status
because a user cannot operate the transceiver due to an accident.
Operating the transceiver
-
-
Note
-
Configuration using FPU
Lone Worker Type
,
Lone Worker Interval
,
Duration of Lone Worker Tone
:
Edit > Emergency Information > General > Lone Worker