5 ANALOG function
120
ACK Delay Time
Type
‘
■
Standard model
■
Basic model
Description
ACK Delay Time
is the length of time from when the transceiver receives data until the transceiver sends the
acknowledgment.
In FleetSync,
ACK Delay Time
must be shorter than
Maximum ACK Wait Time
configured for the transmitting
transceiver.
Operating the transceiver
-
-
Note
-
Configuration using FPU
ACK Delay Time
:
Edit > FleetSync > Parameter
Edit > MDC-1200 > Parameter
Maximum ACK Wait Time
: Edit > FleetSync > Parameter
MDC-1200 - ID List
Type
‘
■
Standard model
■
Basic model
Description
If making Selective Calls, the desired MDC-1200 IDs need to be preconfigured in the transceiver using KPG-D6/
D6N prior to use of the transceiver. A maximum of 1,000 MDC-1200 IDs can be configured in the ID List.
ID List
Configuration
Description
ID Type
The call type can be configured by selecting one of the four options:
“Individual
Call”, “Group Call”, “Fleet Call” or “All Call”.
The configurable IDs vary as follows depending on the
ID Type
configuration.
Individual Call:
Only ID can be configured.
Group Call:
Only Fleet ID and Group ID can be configured.
Fleet Call:
Only Fleet ID can be configured.
All Call:
ID, Fleet ID and Group ID cannot be configured.
ID
An ID can be configured in the range between 0001 and DFFF.
Fleet ID
A Fleet ID can be configured in the range between 0 and F.
Group ID
A Group ID can be configured in the range between 00 and FF.
ID Name
The caller’s ID Name is configured. A maximum of 14 characters can be
configured for the ID Name.
If the ID Name of the transmitting transceiver is configured in the ID
List, the ID Name of the transmitting transceiver appears when the
transceiver receives a Selective Call.
ACK Request
When
ACK Request
is enabled, a response from the receiving transceiver can be
requested when sending a Call Alert. The transceiver waits for response from the
receiving transceiver after sending a Call Alert. If a response is not received from
the receiving transceiver after the time interval configured in
Maximum ACK
Wait Time
has elapsed, a Call Alert will be sent out for a number of times as
configured in
Number of Retries
.
Alert Tone
Selcall:
The type of tone to be sounded from the transceiver can be configured for a
Selective Call from an MDC-1200 ID configured in the ID List.
Call Alert:
The type of tone to be sounded from the transceiver can be configured for a Call
Alert from an
MDC-1200 ID configured in the ID List.
Alert LED
Selcall:
The color of the flashing LED can be configured for a Selective Call from an
MDC-1200 ID
configured in the ID List.
Call Alert:
The color of the flashing LED can be configured for a Call Alert from an
MDC-1200 ID configured in the ID List.
Operating the transceiver
-
-
Note
To use
Alert LED
,
Selective Call Alert LED
needs to be enabled.
Configuration using FPU
ID Type
,
ID
,
Fleet ID
,
Group ID
,
ID Name
,
ACK Request
, A
lert Tone (Selcall, Call Alert)
,
Alert LED (Selcall,
Call Alert)
:
Edit > MDC-1200 > ID List