background image

Technical
Information
TI 372P/24/ae

Pressure Transmitter
cerabar T PMP 135

Pressure transmitter for hygienic processes
For absolute and gauge pressures up to 500 psi
Flush-mounted process connections with
metal diaphragm

The Power of Know How

Application

The Cerabar T PMP 135 is a pressure
transmitter for hygienic applications, e.g.
in the food processing and pharmaceuti-
cal industries.  It is designed for measur-
ing absolute and gauge pressures in
gases, vapors, liquids and dust.
• Finely graduated measuring ranges

up to 500 psi

• Electronic versions include:

- 4 to 20 mA analog output
- Switch output (PNP)

Features and benefits

The PMP 135 is a compact, low cost
pressure transmitter, engineered for
hygienic processes.
• Flush-mounted process connections

with metal diaphragm

• Hygienic design as per 3-A guidelines
• Analog output accuracy 

 0.5%, PNP

switch point deviation 

 1%

• Up to 5 times overload resistant and

excellent longterm stability (0.15%
per year)

• Process temperature, -13° to +212°F;

maximum temperature 275°F (1 hour)

• Optional 3.1.B inspection certificate
• Wetted materials made of 316L SS

with a surface quality of R

a

 

 0.8 

µ

m

(better than 150 grit)

Содержание Cerabar T PMP 135

Страница 1: ...uids and dust Finely graduated measuring ranges up to 500 psi Electronic versions include 4 to 20 mA analog output Switch output PNP Features and benefits The PMP 135 is a compact low cost pressure tr...

Страница 2: ...ustable hysteresis compares this signal with the pre set switch point and then activates the transistor output and LED display Cerabar T PMP 135 pressure transmitter with 4 to 20 mA analog output Powe...

Страница 3: ...relays contactors solenoid valves when directly connected to a protective circuit diode or capacitor Switch PNP output Output current Power Switch frequency Input PLC Inductive loads Power supply Cab...

Страница 4: ...n green 1 Plug with 1 2 NPT or Pg 11 2 M 12 x 1 lug R External load e g relay programmable logic controller distributed control system PNP switch connection Supply voltage Residual ripple Cable entry...

Страница 5: ...adjustments Mounting position Operating conditions environment 13 to 158 F 25 to 70 C 40 to 185 F 40 to 85 C 4 Z with Z 158 F 70 C as per VDI VDE 3540 NEMA 4X IP 65 with 1 2 NPT or Pg 11 cable entry N...

Страница 6: ...lamp 1 or 1 1 2 ISO 2852 Tri clamp 2 ISO 2852 G 1A ISO 228 with tapered metallic seal G 1A ISO 228 with sealing surface for flush mounted installation SMS 1 1 2 1 2 3 4 5 6 6 1 2 NPT Pg 11 M 12 16 ft...

Страница 7: ...ro point can be adjusted for the Cerabar T with analog output and plug version PNP switch output switch point and hysteresis adjustment The Cerabar T with PNP switch output allows adjustment of both t...

Страница 8: ...0 ON red LED OFF green LED Switch on Switch off p Uout on off Certificates and approvals CE mark By attaching the CE mark Endress Hauser confirms that the instrument fulfills all the requirements of t...

Страница 9: ...150 psi Q4N 0 to 50 psi 240 psi Q4R 0 to 150 psi 600 psi Q4S 0 to 300 psi 1500 psi Q4T 0 to 500 psi 2400 psi A1G 0 to 1 bar 0 to 100 kPa 4 bar A1H 0 to 1 6 bar 0 to 160 kPa 6 4 bar A1N 0 to 2 5 bar 0...

Страница 10: ...N selection order code Material 316L SS Gasket enclosed silicon o ring Order number 52001051 Optional with 3 1 B inspection certificate Order number 52011196 Welding aid dummy plug for welding the bo...

Страница 11: ...og signal through the 4 to 20 mA current loop Refer to TI 063R 24 ae Supplemental documentation Cerabar T PMP 131 pressure transmitter with polysilicon sensor TI 291P 24 ae Cerabar T PMC 131 pressure...

Страница 12: ...n ON L7S 1W3 Phone 905 681 9292 800 668 3199 FAX 905 681 9444 Mexico Endress Hauser Paseo del Pedregal No 610 Col Jardines del Pedregal 01900 Mexico D F Mexico Phone 525 568 2405 FAX 525 568 7459 For...

Отзывы: