Series 2280 Precision DC Power Supply Reference Manual
Section 2: General operation
077085503 / March 2019
2-21
Trigger menu
This menu allows you to configure triggering operations from the Series 2280 front panel. The
following topics describe the settings that are available on these interactive screens.
Trigger Configure menu
This menu allows you to configure the triggering operations. The Series 2280 has two trigger layers:
Arm layer and trigger layer.
Setting
Description
List type
Displays the list type when the list function is enabled. The Series 2280
supports the following types of lists:
Step:
One trigger signal will output one list step.
Sweep:
One trigger signal will output the entire list.
Disable:
The list is disabled.
Idle
Cont:On:
Continuous trigger is on.
Cont:Off:
Continuous trigger is off and no readings are taken.
Arm Source
Select the control source for the arm layer.
Arm Count
Set the number of times to repeat the arm event.
Trigger Source
Select the control source for the trigger layer.
Trigger Count
Set the number of times to repeat the trigger event.
Reset Configuration
Reset the trigger settings to factory default, including trigger source and
trigger count.
Sample Count
Set the number of measurements to be performed when a measurement is