KC-P30
Technical data
Installation manual V3.28
54
© KEBA
Power loss
Socket:
20 W at 22 kW
Cable (4 m):
70 W at 22 kW
Cable (6 m):
100 W at 22 kW
Supply terminals
Type:
Spring-type terminal
Cable feed:
Top (surface), back side (flush)
Connection cross-section of the supply:
Minimum cross-section (depending on the
cable and the type of installation)
●
16 A rated current:
5 x 2.5 mm
2
●
32 A nominal current:
5 x 6.0 mm
2
Cross section:
●
Rigid / flexible:
0.2 – 16 mm
2
●
Flexible with wire end sleeve with / with-
out plastic sleeve:
0.25 – 10 mm
2
AWG:
24 – 6
Stripping length:
12 mm
Temperature rating:
105 °C
12.3
Cable / Socket
Cable versions:
(For rating, see rating plate on the cable)
●
Type 1 cable: up to 32 A / 230 V AC in
accordance with EN 62196-1 and SAE-
J1772
●
Type 2 cable: up to 32 A / 400 V AC in
accordance with EN 62196-1 and VDE-
AR-E 2623-2-2
Socket variants:
●
Type 2 standard socket: 32 A /
400 V AC in accordance with
EN 62196-1 and VDE-AR-E 2623-2-2
●
Type 2 standard socket: 32 A /
400 V AC in accordance with
EN 62196-1 and VDE-AR-E 2623-2-2
with Shutter
12.4
Ambient conditions
Use:
Inside and outside area
Access limitations at set-up location:
Limited and unlimited access
Installation (stationary):
On the wall or on a floor-mounted column.
Operating temperature:
●
16 A:
-25 °C to +50 °C (without direct sunlight)
●
32 A:
-25 °C to +40 °C (without direct sunlight)
Storage temperature:
-25 °C to +80 °C