D3DP 3xx/x
Connections and wiring
Project engineering manual V1.00
56
© KEBA
6.11.1
Connection of an external braking resistor X30A (BR)
Designation
Termi
nal
Specification
X30A (BR)
BR
●
Connection braking resistor
●
Connection crosssection for the Terminal: max. 6 mm
2
●
Technical data
ϑ
Connection temperature monitoring Braking resistor
1)
The cable to the ext. braking resistor must be shielded and both ends must
be connected to the related housing. The shield connection on the supply
module is made via the shield plate on the connector BR. The braking resis
tor is normally installed in a metal housing. If the braking resistor is mounted
on a metal, conductive base plate, the shield connection at the braking resis
tor can be made using a shield clamp on the base plate as close as possible
to the braking resistor.
DANGER!
●
Terminal BR is permanently connected to DC link potential (> 300 V
DC).
●
The connection is not protected inside the device.
●
Never wire or disconnect electrical connections while they are live!
●
Always disconnect the power before working on the device.
●
Dangerously high voltages ≥ 50 V (capacitor charge) may still be present
3 minutes after the power is cut.
For the temperature monitoring the external braking resistor must have a
temperature sensor (Klixon) that is to be connected to X1ϑ. In the event of
overtemperature, the temperature evaluation in the supply module reacts
and sends a stop command to all axis modules. The drives then coast down.
Information
The Klixon sensor must have, as a minimum, basic isolation as per
EN6180051 in relation to the body of the resistor at mains potential.
Содержание D3DP 3 Series
Страница 1: ...D3 DP 3xx x Supply module Project engineering manual V 1 00 Translation of original manual ...
Страница 4: ...D3 DP 3xx x Project engineering manual V1 00 4 KEBA ...
Страница 8: ...D3 DP 3xx x Table of Contents Project engineering manual V1 00 8 KEBA ...
Страница 74: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 74 KEBA 14 Declaration of conformity ...
Страница 75: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 75 KEBA ...
Страница 76: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 76 KEBA ...
Страница 77: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 77 KEBA ...
Страница 80: ...D3 DP 3xx x Glossary Project engineering manual V1 00 80 KEBA Glossary ...
Страница 81: ...D3 DP 3xx x Index Project engineering manual V1 00 81 KEBA Index ...
Страница 82: ...D3 DP 3xx x Index Project engineering manual V1 00 82 KEBA ...