D3DP 3xx/x
Connections and wiring
Project engineering manual V1.00
47
© KEBA
Illustration 624: EtherCAT terminal (X40A / X40B)
For shielded connection up to a length of ≤ 20 m the following tested cable
or an equivalent cable must be used:
●
"Silverline Gold" Cat. 7 patch cable, S/STP 4x2x0,14 mm
2
, twisted pair
and shielded data cable with characteristic impedance R
w
= 100 Ω ±15
%
Information
For cable lengths ≥ 20 m special installation cables with larger crosssec
tions are to be used.
All modules (axis and supply modules) have enclosed suitable EtherCAT
cables. They can be used for a connection to the left, nearby module.
Description
Terminal
Specification
X40A EtherCAT IN input
EtherCAT
X40A
Connection via RJ45 connec
tor
X40B EtherCAT OUT output
EtherCAT
X40B
6.6
Specification connection "State" (X20A)
Designation
Terminal
Details
X20A
●
RO0 2 = normally
closed contact
●
RO0 4 = changeover
contact
●
RO0 1 = normally open
contact
●
Relay contact: ≤ 50 V
AC max. 0.5 A(ohmic
load)
●
Contact freely program
mable
●
Factory setting = Active
on Error
Содержание D3DP 3 Series
Страница 1: ...D3 DP 3xx x Supply module Project engineering manual V 1 00 Translation of original manual ...
Страница 4: ...D3 DP 3xx x Project engineering manual V1 00 4 KEBA ...
Страница 8: ...D3 DP 3xx x Table of Contents Project engineering manual V1 00 8 KEBA ...
Страница 74: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 74 KEBA 14 Declaration of conformity ...
Страница 75: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 75 KEBA ...
Страница 76: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 76 KEBA ...
Страница 77: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 77 KEBA ...
Страница 80: ...D3 DP 3xx x Glossary Project engineering manual V1 00 80 KEBA Glossary ...
Страница 81: ...D3 DP 3xx x Index Project engineering manual V1 00 81 KEBA Index ...
Страница 82: ...D3 DP 3xx x Index Project engineering manual V1 00 82 KEBA ...