D3DP 3xx/x
Connections and wiring
Project engineering manual V1.00
55
© KEBA
6.10.1
Terminal position top side X30A (BR) and X01C (24 V DC)
Illustration 631: Terminal position top side (size 1 and 2)
6.11
Braking chopper connection
In regenerative operation, e.g. when braking the drive, the motor feeds en
ergy back to the axis module. This increases the voltage in the DC link. If the
voltage exceeds a threshold value, the internal braking transistor is activated
and the regenerated power is converted into heat by means of a braking re
sistor.