Operation of the Unit
4.
Operation of the Unit
4.1
Operation Accessories
4.1.1 With HSP5 cable and without operator
A special cable (part number 00F50C0-0001) is necessary for the control of the KEB
COMBIVERT without operator. It is connected between the HSP5-interface X4A and a
serial RS232-PC-interface (COM1 or COM2). The operation takes place via the PC-program
COMBIVIS.
The HSP5-cable has an integrated level converter. The connection of a serial
standard cable would destroy the PC-interface.
4.1.2 Digital operator (part number 00F5060-1000)
As an accessory for the local operation of the KEB COMBIVERT F5 an operator is available.
To prevent malfunctions, the inverter must be brought into nOP status before connecting /
disconnecting the operator (open control release). When starting the inverter, it is always
started with the last stored values or the factory setting.
4.1.3 Interface operator (part number 00F5060-2000)
The interface operator corresponds to the functional range of the digital operator. However,
it is enhanced by a serial RS232/485-interface.
A RS232-cable is needed to connect the interface operator with the PC. The assignment
is represented on the following page.
5 4 3 2 1
9 8 7 6
5-digit LED Display
Operating-/Error display
Normal "LED on"
Error "LED blinks"
Double function keyboard
RS232/RS485
(only 00F5060-2000)
Interface control
Transmit "LED on"
(only 00F5060-2000)
START
FUNC.
SPEED
ENTER
F/R
STOP
C O M B I V E R T
X6C
X6D
X6B
HSP5 diagnostic interface
(only 00F5060-2000)
PIN RS485
Signal Meaning
1
-
-
reserved
2
-
TxD
transmission signal RS232
3
-
RxD
receive signal RS232
4
A‘
RxD-A receive signal A RS485
5
B‘
RxD-B receive signal B RS485
6
-
VP
Voltage 5 V (Imax=50 mA)
7
C/C‘
DGND Data reference potential
8
A
TxD-A transmission signal A RS485
9
B
TxD-B transmission signal B RS485