GB - 34
CP-Parameter
4.3
Parameter description for F5 servo
Display Parameter
Setting Range Resolution Default Unit ENTER Based on
CP.00 Password input
0...9999
1
-
-
-
ud.01
CP.01 Encoder 1 speed
±4000
0.125
0
rpm
-
ru.09
CP.02 Setpoint display
±4000
0.125
0
rpm
-
ru.01
CP.03 Inverter state
0...255
1
0
-
-
ru.00
CP.04 Apparent current
0...6553.5
0.1
0
A
-
ru.15
CP.05 Apparent current / peak value
0...6553.5
0.1
0
A
-
ru.16
CP.06 Actual torque display
±10000.00
0.01
0
Nm
-
ru.12
CP.07 DC-link voltage
0...1000
1
0
V
-
ru.18
CP.08 DC-link voltage / peak value
0...1000
1
0
V
-
ru.19
CP.09 Output voltage
0...778
1
0
V
-
ru.20
CP.10 Speed control configuration
4...6
1
4
-
-
cs.00
CP.11 DSM rated torque
0.1...6553.5
0.1
LTK
Nm
-
dr.27
CP.12 DSM rated speed
0...32000
1
LTK
rpm
-
dr.24
CP.13 DSM rated frequency
0.0...1600.0
0.1
LTK
Hz
-
dr.25
CP.14 DSM rated current
0.0...710.0
0.1
LTK
A
-
dr.23
CP.15 DSM EMK voltage constant
0...1000
1
LTK
V
-
dr.26
CP.16 DSM winding inductance
0.01...500.00
0.01
LTK
mH
-
dr.31
CP.17 DSM winding resistance
0.000...50.000
0.001
LTK
Ω
-
dr.30
CP.18 DSM current for zero speed
0.0...700.0
0.1
LTK
A
-
dr.28
CP.19 Load motor dependent parameter
0...3
1
1
-
E
fr.10
CP.20 Absolute position enc.1
0...65535
1
57057
-
-
ec.02
CP.21 Encoder 1 rotation
0...19
1
0
-
-
ec.06
CP.22 max. reference forward
0...4000
0.125
2100
rpm
-
op.10
CP.23 Step value 1
±4000
0.125
100
rpm
-
op.21
CP.24 Step value 2
±4000
0.125
-100
rpm
-
op.22
CP.25 Acceleration time
0.00...300.00
0.01
5
s
-
op.28
CP.26 Deceleration time
-0.01...300.00
0.01
5
s
-
op.30
CP.27 S-curve time
0.00...5.00
0.01
0
s
-
op.32
CP.28 Torque reference source
0...5
1
2
-
E
cs.15
CP.29 Abs. torque reference
±10000.00
0.01
LTK
Nm
-
cs.19
CP.30 KP speed
0...32767
1
50
-
-
cs.06
CP.31 KI speed
0...32767
1
500
-
-
cs.09
CP.32 Switching frequency
0...LTK
1
LTK
-
E
uf.11
CP.33 Relay output 1 / function
0...78
1
4
-
E
do.2
CP.34 Relay output 2 / function
0...78
1
2
-
E
do.3
CP.35 Limit switch / stopping mode
0...6
1
6
-
-
pn.7
CP.36 External Fault / stopping mode
0...6
1
0
-
-
pn.3
CP.3 Inverter state
In parameter „inverter status“ the actual operating condition of the frequency inverter
is displayed. In the case of an error the current error message is displayed, even if the
display has already been reset with ENTER (error-LED on the operator is still blinking).
Status messages and information about the cause and removal are to be found in www.
keb.de => Documentation => Operating Instructions => Other => Service informations =>
Error and status messages.doc.