GB - 20
4.2.2 Resetting error messages
If a malfunction occurs during operation, then the actual display is overwritten by the alarm
message. The alarm message in the display is reset by ENTER.
— Error —>
ENTER
F/R
With ENTER only the error message in the display is reset. In order to reset
the error itself, the cause must be removed or a power-on reset must be made.
4.2.3 Password Input
The KEB COMBIVERT is outfitted with a comprehensive password protection. In dependence
on the entered password the following modes are possible:
Display Mode
CP_ro End customer menu (CP-Parameter) read-only
CP_on End customer menu (CP-Parameter) read/write
CP_SE Service menu (like end customer menu, but with the original parameters )
APPL
Application menu (all parameter groups and parameters are visible)
–
Drive mode (COMBIVERT can be put into operation by the keyboard )
The menu admissible for the application is defined by the machine builder. The password
input is generally made over the parameter CP.0. The adjusted password/menu is maintained
even after switching off.
Example: Changing the CP-parameter from read-only to read/write
Password
FUNC
ENTER
UP
Operation of the Unit